{"product_id":"icc-ust-installation-retrofitting-u1-book-package","title":"ICC UST Installation\/Retrofitting - U1 - Book Package","description":"\u003ch1 style=\"color: #d32f2f;\"\u003eICC UST Installation\/Retrofitting - U1 - Book Package\u003c\/h1\u003e\n\u003cp\u003eThe ICC UST Installation\/Retrofitting - U1 - Book Package is designed for students preparing for the ICC UST Installation\/Retrofitting U1 exam using the listed underground storage tank installation, vapor recovery, flammable and combustible liquids, motor fuel dispensing, UST equipment testing, EPA technical standards, and inspector safety references. This package includes \u003cem\u003eRP100 UST Installation: Recommended Practices for Installation of Underground Liquid Storage Systems, 2017\u003c\/em\u003e, \u003cem\u003ePEI\/RP 300 Recommended Practices for Installation and Testing of Vapor Recovery Systems at Vehicle Fueling Sites, PEI, 2019\u003c\/em\u003e, \u003cem\u003eNFPA 30, Flammable and Combustible Liquids Code, 2018\u003c\/em\u003e, \u003cem\u003eNFPA 30A Code for Motor Fuel Dispensing Facilities and Repair Garages, 2018\u003c\/em\u003e, \u003cem\u003ePEI\/RP 1200 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities, PEI, 2017\u003c\/em\u003e, \u003cem\u003eEPA 40 C.F.R. Part 280.10-280.74 Technical Standards and Corrective Action Requirements for Owners and Operators of USTs\u003c\/em\u003e, and \u003cem\u003eEPA 910\/B-92\/001 Health and Safety Training for Underground Storage Tank Inspectors, Student’s Guide\u003c\/em\u003e.\u003c\/p\u003e\n\u003cp\u003eThis book package supports focused preparation for underground storage tank installation and retrofitting, petroleum equipment installation, tank excavation, bedding, backfill, piping, containment, spill prevention, overfill prevention, leak detection, secondary containment, dispenser system coordination, vapor recovery systems, flammable and combustible liquid safety, motor fuel dispensing facility requirements, environmental compliance, and site safety. Students preparing for the U1 exam should understand the technical requirements that apply to UST systems, along with the safety and regulatory responsibilities connected to installation and retrofit work.\u003c\/p\u003e\n\u003cp\u003eUST installation and retrofitting requires careful coordination between environmental protection, fire safety, equipment installation, manufacturer instructions, recommended practices, regulatory standards, and jobsite safety. Underground storage tank systems may include tanks, piping, containment sumps, spill buckets, overfill prevention equipment, leak detection equipment, vapor recovery components, dispensers, vent systems, corrosion protection, monitoring equipment, and required records. A strong study plan should help students understand how these components work together as a complete fuel storage and dispensing system.\u003c\/p\u003e\n\u003cp\u003eThis package is useful for petroleum equipment contractors, UST installers, retrofit technicians, environmental compliance personnel, fuel system service professionals, tank system inspectors, fire prevention personnel, facility owners, convenience store operators, code students, and individuals preparing for ICC certification. The references in this package help students study underground tank system installation from multiple angles: recommended installation practice, vapor recovery, fire and liquid hazard safety, dispenser facility requirements, EPA compliance, equipment testing, and inspector health and safety.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eWhat You Get\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eBook:\u003c\/strong\u003e RP100 UST Installation: Recommended Practices for Installation of Underground Liquid Storage Systems, 2017\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBook:\u003c\/strong\u003e PEI\/RP 300 Recommended Practices for Installation and Testing of Vapor Recovery Systems at Vehicle Fueling Sites, PEI, 2019\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBook:\u003c\/strong\u003e NFPA 30, Flammable and Combustible Liquids Code, 2018\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBook:\u003c\/strong\u003e NFPA 30A Code for Motor Fuel Dispensing Facilities and Repair Garages, 2018\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBook:\u003c\/strong\u003e PEI\/RP 1200 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities, PEI, 2017\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBook:\u003c\/strong\u003e EPA 40 C.F.R. Part 280.10-280.74 Technical Standards and Corrective Action Requirements for Owners and Operators of USTs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBook:\u003c\/strong\u003e EPA 910\/B-92\/001 Health and Safety Training for Underground Storage Tank Inspectors, Student’s Guide\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStudy Focus:\u003c\/strong\u003e UST installation, retrofitting, tank excavation, bedding, backfill, piping, spill prevention, overfill prevention, leak detection, secondary containment, vapor recovery, dispenser coordination, flammable and combustible liquid safety, EPA compliance, equipment testing, and jobsite safety.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eExam Details\u003c\/h2\u003e\n\u003cp\u003eThe ICC UST Installation\/Retrofitting U1 exam focuses on technical knowledge related to underground storage tank installation and retrofit work. Students preparing for this exam should study the listed references to build familiarity with tank system components, petroleum equipment installation, environmental protection requirements, fire safety standards, vapor recovery systems, equipment testing, and site safety practices.\u003c\/p\u003e\n\u003cp\u003eU1 exam preparation should include tank installation concepts such as excavation, tank handling, placement, bedding, backfill, anchoring where applicable, piping layout, venting, containment, corrosion protection, spill prevention, overfill prevention, leak detection, testing, and documentation. Students should also understand retrofit work, which may involve adding, replacing, upgrading, or verifying components on existing underground storage tank systems.\u003c\/p\u003e\n\u003cp\u003eRP100 is a key reference for UST installation practices. Students should use it to study recommended procedures for installing underground liquid storage systems, including site preparation, tank handling, excavation safety, tank placement, backfill requirements, piping installation, equipment connection, testing, and completion documentation. Because installation quality affects system performance and environmental protection, this reference should receive careful study.\u003c\/p\u003e\n\u003cp\u003ePEI\/RP 300 supports preparation for vapor recovery system installation and testing at vehicle fueling sites. Students should review vapor recovery components, piping, testing procedures, system verification, dispenser coordination, and installation requirements related to vehicle fueling operations. Vapor recovery systems may be part of the facility’s environmental control strategy and must be understood in relation to the fuel system as a whole.\u003c\/p\u003e\n\u003cp\u003eNFPA 30 and NFPA 30A support fire and fuel facility safety topics. NFPA 30 covers flammable and combustible liquid safety, while NFPA 30A addresses motor fuel dispensing facilities and repair garages. Students should study fuel hazards, dispenser locations, emergency shutoffs, ignition source control, liquid storage, dispensing operations, and safety requirements that affect UST installation and retrofitting at fueling facilities.\u003c\/p\u003e\n\u003cp\u003ePEI\/RP 1200 supports testing and verification of spill prevention, overfill prevention, leak detection, and secondary containment equipment. This reference is important because many UST retrofit projects involve verifying or upgrading the equipment that helps prevent releases and detect problems. EPA 40 C.F.R. Part 280.10-280.74 supports regulatory requirements for owners and operators, while the EPA health and safety guide supports awareness of jobsite hazards around UST systems.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eClosed Book Test\u003c\/h2\u003e\n\u003cp\u003eThe ICC UST Installation\/Retrofitting U1 exam is identified as a closed book test. This means students should not rely on looking up answers during the exam. Preparation should focus on understanding the material before exam day, building memory around major concepts, and recognizing how UST installation requirements, safety practices, and environmental compliance topics work together.\u003c\/p\u003e\n\u003cp\u003eClosed book testing requires a different study approach than open book code exams. Students should still study the references thoroughly, but the goal is to retain the major principles, system components, installation steps, inspection concepts, hazard controls, and regulatory themes. Students should review topic summaries, create flashcards, take practice questions, and explain system functions without looking at the books.\u003c\/p\u003e\n\u003cp\u003eA helpful closed-book strategy is to group the material by system function. Students can study tank placement and excavation first, then piping and containment, then spill and overfill prevention, then leak detection and secondary containment, then vapor recovery, then fire safety, then EPA compliance, and finally jobsite health and safety. Organizing the material this way helps students connect the references to real installation and retrofit work.\u003c\/p\u003e\n\u003cp\u003eStudents should pay special attention to recurring UST concepts such as release prevention, leak detection, containment, overfill protection, corrosion protection, dispenser coordination, vapor control, testing, documentation, and safety around petroleum systems. These subjects appear throughout the references and are central to UST installation and retrofitting work.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eLicensing Steps\u003c\/h2\u003e\n\u003cp\u003eThe ICC UST Installation\/Retrofitting U1 credential is earned through the International Code Council certification exam process. Students preparing for the exam should begin by reviewing the listed references, identifying the major topics covered by each book, and creating a study plan that supports closed-book recall.\u003c\/p\u003e\n\u003cp\u003eA practical preparation path begins with RP100. Students should study the recommended practices for underground liquid storage system installation, including excavation, bedding, backfill, tank placement, piping, fittings, containment, venting, anchoring where applicable, system testing, and documentation. This reference supports the core installation portion of the exam package.\u003c\/p\u003e\n\u003cp\u003eStudents should then review PEI\/RP 300 for vapor recovery systems and PEI\/RP 1200 for testing and verification of UST equipment. These references support important retrofit and verification topics, including vapor recovery system installation, spill prevention equipment, overfill prevention equipment, leak detection equipment, and secondary containment components.\u003c\/p\u003e\n\u003cp\u003eNFPA 30 and NFPA 30A should be studied for fuel safety and motor fuel dispensing facility requirements. Students should understand flammable and combustible liquid hazards, ignition source control, dispensing safety, emergency shutoff concepts, and fuel facility coordination. EPA regulations should be reviewed for technical standards, corrective action concepts, owner and operator responsibilities, release prevention, release detection, and environmental compliance.\u003c\/p\u003e\n\u003cp\u003eStudents should also review the EPA health and safety training guide. Installation and retrofitting work can involve excavation hazards, flammable vapors, petroleum exposure, contaminated soil or water, moving equipment, vehicle traffic, electrical hazards, and confined or restricted spaces. Safety awareness is a key part of responsible UST work.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eState Requirements\u003c\/h2\u003e\n\u003cp\u003eThe ICC UST Installation\/Retrofitting U1 exam is a national ICC certification exam. It supports credentialing for professionals involved in underground storage tank installation, retrofitting, petroleum equipment work, fuel storage system compliance, and environmental protection.\u003c\/p\u003e\n\u003cp\u003eEmployment, licensing, registration, or recognition as a UST installer, retrofit technician, petroleum equipment contractor, fuel system installer, environmental compliance technician, or tank system professional may depend on the requirements of a state environmental agency, fire marshal, local jurisdiction, employer, contractor licensing board, or authority having jurisdiction. Additional approvals, company licensing, technician licensing, field experience, training, continuing education, insurance, or state-specific credentials may apply.\u003c\/p\u003e\n\u003cp\u003eThis book package focuses on the study references for the ICC U1 exam. Students should use the listed references to prepare for the technical exam content while also following the requirements of the jurisdiction, agency, employer, or authority connected to the UST systems they install, retrofit, inspect, or service.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eReference Books\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRP100 UST Installation: Recommended Practices for Installation of Underground Liquid Storage Systems, 2017\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA recommended practice used to study underground liquid storage system installation, including excavation, tank handling, bedding, backfill, piping, tank placement, system components, testing, and installation documentation.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePEI\/RP 300 Recommended Practices for Installation and Testing of Vapor Recovery Systems at Vehicle Fueling Sites, PEI, 2019\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA vapor recovery reference used to study vapor recovery system installation, testing, piping, dispenser coordination, component verification, and vehicle fueling site vapor control practices.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNFPA 30, Flammable and Combustible Liquids Code, 2018\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA flammable and combustible liquids reference used to study liquid hazards, storage safety, fire prevention, spill control, ignition source control, tank and container requirements, and safeguards for flammable and combustible liquid systems.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNFPA 30A Code for Motor Fuel Dispensing Facilities and Repair Garages, 2018\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA motor fuel dispensing facility reference used to study fuel dispensing requirements, dispenser safety, emergency shutoff provisions, repair garage provisions, fueling area protection, and coordination of fuel system equipment.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePEI\/RP 1200 Recommended Practices for the Testing and Verification of Spill, Overfill, Leak Detection and Secondary Containment Equipment at UST Facilities, PEI, 2017\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA testing and verification reference used to study spill prevention equipment, overfill prevention equipment, leak detection equipment, secondary containment equipment, containment sumps, spill buckets, and related UST facility testing practices.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPA 40 C.F.R. Part 280.10-280.74 Technical Standards and Corrective Action Requirements for Owners and Operators of USTs\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA federal regulatory reference used to study UST technical standards, owner and operator responsibilities, release prevention, release detection, spill and overfill control, corrosion protection, corrective action concepts, closure, and recordkeeping.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEPA 910\/B-92\/001 Health and Safety Training for Underground Storage Tank Inspectors, Student’s Guide\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eA safety training reference used to study inspector health and safety, petroleum hazards, vapor concerns, contaminated media awareness, personal protective equipment concepts, jobsite hazards, and safe work practices around tank systems.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eTest Information and Study Materials\u003c\/h2\u003e\n\u003cp\u003eThe U1 exam requires students to study underground storage tank installation and retrofitting as a technical, environmental, and safety-focused subject. Students should begin by understanding the major parts of a UST system, including the tank, piping, venting, spill prevention equipment, overfill prevention equipment, containment sumps, leak detection equipment, vapor recovery components, dispensers, corrosion protection, and monitoring equipment.\u003c\/p\u003e\n\u003cp\u003eInstallation practices should receive focused study time. Students should review excavation planning, tank handling, tank placement, bedding, backfill, anchoring where applicable, piping installation, slope, fittings, venting, containment, equipment access, and system testing. Installation questions may require students to understand both the sequence of work and the purpose of each installation requirement.\u003c\/p\u003e\n\u003cp\u003eRetrofitting topics should also be studied carefully. Retrofit work may involve upgrading existing UST systems with new spill prevention equipment, overfill prevention devices, leak detection equipment, secondary containment components, vapor recovery equipment, or piping improvements. Students should understand that retrofit work must account for the existing system condition, component compatibility, safety during work, and compliance with applicable requirements.\u003c\/p\u003e\n\u003cp\u003eVapor recovery should be studied through PEI\/RP 300. Students should review vapor piping, testing, dispenser coordination, system verification, and the role of vapor control at vehicle fueling sites. Vapor recovery systems must be understood as part of the full fuel dispensing operation.\u003c\/p\u003e\n\u003cp\u003eSpill prevention, overfill prevention, leak detection, and secondary containment should be reviewed through PEI\/RP 1200 and EPA regulations. Students should understand why these systems are required, how they reduce release risk, how they are verified, and why proper installation and testing are essential for compliance.\u003c\/p\u003e\n\u003cp\u003eFire safety should be studied through NFPA 30 and NFPA 30A. Students should understand the hazards of flammable and combustible liquids, ignition source control, emergency shutoffs, fueling facility safety, dispenser installation concepts, repair garage considerations, and general fire prevention principles that affect UST work.\u003c\/p\u003e\n\u003cp\u003eHealth and safety topics should not be overlooked. Students should review petroleum vapor hazards, excavation safety, contaminated soil or water, personal protective equipment concepts, traffic hazards, electrical hazards, slips and falls, and safe inspection practices. Tank system work can present serious hazards, and safety awareness is part of responsible installation and retrofitting preparation.\u003c\/p\u003e\n\u003cp\u003eThe best study strategy for a closed-book exam combines reading, repetition, and active recall. Students should summarize major topics, review key definitions, quiz themselves on system components, create study cards for safety and compliance concepts, and practice explaining installation requirements without looking at the references. The goal is to understand the material well enough to apply it from memory during the exam.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eHow 1 Exam Prep Helps You Reach Your Goal\u003c\/h2\u003e\n\u003cp\u003e1 Exam Prep helps students prepare for the ICC UST Installation\/Retrofitting U1 exam by organizing the key references needed for focused study. This book package supports students who want to build familiarity with underground storage tank installation, retrofit work, petroleum equipment systems, vapor recovery, fuel dispensing facilities, environmental compliance, equipment testing, and jobsite safety.\u003c\/p\u003e\n\u003cp\u003eClosed book exams reward students who understand the material before exam day. Many students are used to open-book code exams, but the U1 closed-book format requires a study routine built around retention and concept recognition. Students should use the references to build memory, strengthen understanding, and connect installation practices with compliance and safety responsibilities.\u003c\/p\u003e\n\u003cp\u003eThis package gives students the books and regulatory materials needed to study the major U1 exam topics. RP100 supports underground storage system installation. PEI\/RP 300 supports vapor recovery installation and testing. NFPA 30 and NFPA 30A support flammable liquid and fueling facility safety. PEI\/RP 1200 supports testing and verification of key UST equipment. EPA materials support technical standards, corrective action concepts, and health and safety awareness.\u003c\/p\u003e\n\u003cp\u003e1 Exam Prep’s approach is practical and exam-focused. Students can use this package to create a study schedule, review major topics, organize the references by subject, and become more comfortable with UST installation and retrofitting language. While no book package can guarantee an exam result, organized preparation can help students improve familiarity, reduce uncertainty, and approach the U1 exam with a stronger plan.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eFAQ Section\u003c\/h2\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eWhat exam does this book package help me prepare for?\u003c\/h2\u003e\n\u003cp\u003eThis package helps students prepare for the ICC UST Installation\/Retrofitting U1 exam. It is focused on underground storage tank installation, retrofitting, vapor recovery, fuel dispensing systems, equipment testing, environmental compliance, and tank system safety.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eWhat books and references are included in this package?\u003c\/h2\u003e\n\u003cp\u003eThis package includes RP100, PEI\/RP 300, NFPA 30, NFPA 30A, PEI\/RP 1200, EPA 40 C.F.R. Part 280.10-280.74, and EPA 910\/B-92\/001 Health and Safety Training for Underground Storage Tank Inspectors, Student’s Guide.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eIs the ICC U1 UST Installation\/Retrofitting exam open book?\u003c\/h2\u003e\n\u003cp\u003eNo. The ICC UST Installation\/Retrofitting U1 exam is identified as a closed book test. Students should study the references thoroughly and prepare to apply the material without relying on reference lookup during the exam.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eWhat topics should I study for the U1 exam?\u003c\/h2\u003e\n\u003cp\u003eStudents should study UST installation practices, retrofitting, tank excavation, bedding, backfill, piping, venting, containment, vapor recovery, spill prevention, overfill prevention, leak detection, secondary containment, motor fuel dispensing facilities, EPA technical standards, and site safety.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eWhich reference is focused on UST installation?\u003c\/h2\u003e\n\u003cp\u003eRP100 is the recommended practice focused on installation of underground liquid storage systems. Students should study it closely for UST installation and retrofitting preparation.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eWhy are NFPA 30 and NFPA 30A included?\u003c\/h2\u003e\n\u003cp\u003eNFPA 30 supports study of flammable and combustible liquid safety, while NFPA 30A supports study of motor fuel dispensing facilities and repair garages. Both references help students understand the fire safety environment surrounding UST fueling systems.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eWhy is PEI\/RP 1200 included?\u003c\/h2\u003e\n\u003cp\u003ePEI\/RP 1200 supports study of testing and verification for spill prevention equipment, overfill prevention equipment, leak detection equipment, and secondary containment equipment at UST facilities.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eDoes this package include a course?\u003c\/h2\u003e\n\u003cp\u003eThis product is a book package. It includes the listed books and references for exam preparation.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eDoes this package include pricing?\u003c\/h2\u003e\n\u003cp\u003ePricing is not listed on this page because no package price was provided for this product.\u003c\/p\u003e\n\u003ch2 style=\"color: #d32f2f;\"\u003eCan this package guarantee that I will pass the exam?\u003c\/h2\u003e\n\u003cp\u003eNo. This package does not guarantee an exam result. It is designed to support preparation by helping students study the required references, organize closed-book review, and build confidence with UST installation and retrofitting topics.\u003c\/p\u003e","brand":"1 Exam Prep","offers":[{"title":"Default Title","offer_id":46122982244409,"sku":null,"price":2645.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1789\/0861\/files\/ICC-USTInstall-Retrofit-U1-BOOKS.jpg?v=1782932164","url":"https:\/\/1examprep.com\/products\/icc-ust-installation-retrofitting-u1-book-package","provider":"1 Exam Prep","version":"1.0","type":"link"}