{"product_id":"washington-equipment-repair-master-electrician-07e-book-package","title":"Washington Equipment Repair Master Electrician 07E Book Package","description":"\u003ch1 style=\"color: #d32f2f;\"\u003eWashington Equipment Repair Master Electrician 07E Book Package\u003c\/h1\u003e\n\n\u003cp\u003ePrepare for the Washington Equipment Repair Master Electrician examination with a focused reference package built around the electrical code, Washington electrical law, and state administrative rules used for the \u003cstrong\u003e07E Equipment Repair specialty\u003c\/strong\u003e. This package includes the \u003cstrong\u003eRevised Code of Washington (RCW) Chapter 19.28\u003c\/strong\u003e, \u003cstrong\u003eWashington Administrative Code (WAC) Chapter 296-46B\u003c\/strong\u003e, and the \u003cstrong\u003eNational Electrical Code, NEC, 2020 Edition\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eWashington officially identifies this specialty as \u003cstrong\u003e07E Equipment Repair\u003c\/strong\u003e. The classification covers servicing, maintaining, repairing, or replacing qualifying utilization equipment. Washington law provides a detailed definition of the utilization equipment covered by this specialty, including how it is constructed, listed or evaluated, connected to electrical power, and limited in voltage.\u003c\/p\u003e\n\n\u003cp\u003eThe Washington 07E Master Electrician examination combines National Electrical Code knowledge, electrical theory, and Washington electrical laws and rules. Candidates should be prepared for questions involving general NEC requirements, wiring and protection, overcurrent protection, grounding and bonding, wiring methods, electrical equipment, motors and related equipment, hazardous locations, special occupancies, special conditions, general trade knowledge, and the Washington-specific scope of Equipment Repair work.\u003c\/p\u003e\n\n\u003cp\u003eWashington electrical examinations are \u003cstrong\u003eopen book\u003c\/strong\u003e. Approved references may be used in the testing center, making effective reference navigation an important part of preparation. Candidates should become comfortable determining whether a question is controlled by the NEC, RCW Chapter 19.28, or WAC Chapter 296-46B and then finding the applicable provision efficiently.\u003c\/p\u003e\n\n\u003cp\u003eThe 07E specialty has a broader voltage range than several of Washington's other restricted maintenance specialties. Qualifying utilization equipment may be connected as a single unit to a single electrical power source of up to \u003cstrong\u003e600 volts\u003c\/strong\u003e. A separate single source of electrical control power may be up to \u003cstrong\u003e250 volts\u003c\/strong\u003e. Those ratings do not make the specialty an unrestricted electrical classification; the equipment must still meet Washington's definition of qualifying utilization equipment, and the work remains subject to specific limitations.\u003c\/p\u003e\n\n\u003cp\u003eThis book package brings together three essential references for organized preparation. The NEC provides technical electrical requirements, RCW Chapter 19.28 establishes Washington electrical law and the statutory 07E scope, and WAC Chapter 296-46B contains the state's detailed specialty, examination, certification, contractor, permit, inspection, supervision, and electrical installation rules.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eWhat You Get\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRevised Code of Washington (RCW) Chapter 19.28\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWashington electrical law governing electricians, Master Electricians, electrical contractors, certification, installations, enforcement, and the statutory scope and definitions for Equipment Repair work.\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWashington Administrative Code (WAC) Chapter 296-46B\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eWashington's detailed electrical safety, licensing, certification, specialty-scope, examination, contractor, supervision, permit, inspection, and installation rules. This reference recognizes Equipment Repair as specialty classification 07E.\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNational Electrical Code, NEC, 2020 Edition\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe NEC edition used for the Washington electrical examination program covered by this package. It provides technical requirements for wiring and protection, overcurrent protection, grounding and bonding, wiring methods, electrical equipment, motors, hazardous locations, special occupancies, and special conditions.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eExam Details\u003c\/h2\u003e\n\n\u003cp\u003eThe Washington \u003cstrong\u003e07E Equipment Repair Master Electrician\u003c\/strong\u003e examination contains two required sections: \u003cstrong\u003eNEC \u0026amp; Theory\u003c\/strong\u003e and \u003cstrong\u003eWashington Codes\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNEC \u0026amp; Theory:\u003c\/strong\u003e Approximately 34 questions\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTime Allowed for NEC \u0026amp; Theory:\u003c\/strong\u003e 2 hours\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWashington Codes:\u003c\/strong\u003e Approximately 20 questions\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTime Allowed for Washington Codes:\u003c\/strong\u003e 1 hour\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTotal Questions:\u003c\/strong\u003e Approximately 54 questions across both sections\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTotal Testing Time:\u003c\/strong\u003e Approximately 3 hours across both sections\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePassing Score:\u003c\/strong\u003e 70% or greater on each required examination section\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eExam Type:\u003c\/strong\u003e Open book\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTesting Provider:\u003c\/strong\u003e PSI\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrimary Code Reference:\u003c\/strong\u003e National Electrical Code, NEC, 2020 Edition\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe published NEC \u0026amp; Theory outline includes approximately one question from NEC Article 90, two from NEC Articles 100 through 110, one involving wiring and protection, four involving overcurrent protection, four involving grounding and bonding, six involving wiring methods, two involving electrical equipment, four involving motors, HVAC equipment, generators and transformers, one involving hazardous locations, one involving special occupancies, two involving special conditions, and approximately six questions involving general trade knowledge and electrical theory.\u003c\/p\u003e\n\n\u003cp\u003eThe Washington Codes section contains approximately 20 questions involving Washington electrical laws and administrative rules. Candidates should prepare for Equipment Repair scope, Master Electrician requirements, contractor responsibilities, examinations, certification, permits, inspections, and limitations on the electrical work permitted under the 07E specialty.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eOpen Book Test\u003c\/h2\u003e\n\n\u003cp\u003eThe Washington Equipment Repair Master Electrician examination is an \u003cstrong\u003eopen book test\u003c\/strong\u003e. Approved reference materials may be brought into the testing center under Washington electrical examination rules.\u003c\/p\u003e\n\n\u003cp\u003eThe \u003cstrong\u003e2020 National Electrical Code\u003c\/strong\u003e is permitted during the examination. Permanent index tabs are acceptable, while removable tabs, sticky notes, and handwritten notes are prohibited. Original copyrighted reference materials may contain highlighting, underlining, and permanent index tabs when they otherwise comply with examination requirements.\u003c\/p\u003e\n\n\u003cp\u003ePrinted copies of \u003cstrong\u003eRCW Chapter 19.28\u003c\/strong\u003e and \u003cstrong\u003eWAC Chapter 296-46B\u003c\/strong\u003e may also be used during testing. Printed Washington electrical laws and rules should be hole-punched and placed in a three-ring binder.\u003c\/p\u003e\n\n\u003cp\u003eBecause the 07E NEC \u0026amp; Theory section contains approximately 34 questions in two hours, candidates should develop efficient navigation habits. Wiring methods, overcurrent protection, grounding and bonding, motors, electrical equipment, and general theory represent important areas of the examination.\u003c\/p\u003e\n\n\u003cp\u003eReference familiarity is equally important for Washington Codes. The 07E scope is defined through both WAC Chapter 296-46B and RCW 19.28.095, so candidates should know how to locate the definition of qualifying utilization equipment, permitted repair activities, voltage limits, supply-whip provisions, and work that is specifically excluded.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eLicensing Steps\u003c\/h2\u003e\n\n\u003cp\u003eWashington Equipment Repair Master Electrician certification is administered through the \u003cstrong\u003eWashington State Department of Labor \u0026amp; Industries\u003c\/strong\u003e. A candidate for a specialty Master Electrician certificate must first hold the corresponding Washington specialty electrician certificate.\u003c\/p\u003e\n\n\u003col\u003e\n  \u003cli\u003e\n\u003cstrong\u003eObtain the 07E Equipment Repair Electrician certificate.\u003c\/strong\u003e The specialty Master Electrician pathway begins with certification in the corresponding Equipment Repair specialty.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eHold the specialty certificate for at least two years.\u003c\/strong\u003e Washington requires an applicant for a master specialty electrician examination to have possessed a valid certificate in the specialty being applied for for two years.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eApply for the Master Electrician examination.\u003c\/strong\u003e Submit the applicable Master Electrician examination application to Washington Labor \u0026amp; Industries.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eReceive L\u0026amp;I examination approval.\u003c\/strong\u003e Labor \u0026amp; Industries reviews the application and verifies that the qualification requirements have been met.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrepare for NEC \u0026amp; Theory.\u003c\/strong\u003e Study the 2020 NEC, emphasizing wiring methods, grounding and bonding, overcurrent protection, motors, equipment, special occupancies, and electrical theory.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePrepare for Washington Codes.\u003c\/strong\u003e Review RCW Chapter 19.28 and WAC Chapter 296-46B, especially RCW 19.28.095 and the 07E specialty provisions.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eSchedule the examination through PSI.\u003c\/strong\u003e Follow the scheduling instructions provided after L\u0026amp;I approval.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eTake both required examination sections.\u003c\/strong\u003e Complete NEC \u0026amp; Theory and Washington Codes.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003ePass each required section.\u003c\/strong\u003e Washington requires a score of at least 70% on every required examination section.\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eComplete the certification process.\u003c\/strong\u003e Follow Washington Labor \u0026amp; Industries requirements for issuance of the 07E Equipment Repair Master Electrician certificate.\u003c\/li\u003e\n\u003c\/ol\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eState Requirements\u003c\/h2\u003e\n\n\u003cp\u003eWashington identifies Equipment Repair as electrical specialty classification \u003cstrong\u003e07E\u003c\/strong\u003e. To qualify for the specialty Master Electrician examination, an applicant must have possessed a valid Washington Equipment Repair specialty electrician certificate for at least \u003cstrong\u003etwo years\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThe underlying 07E Equipment Repair Electrician certification requires \u003cstrong\u003e2,000 hours of qualifying work experience\u003c\/strong\u003e. A trainee may become eligible for the 07E specialty electrician examination after completing at least \u003cstrong\u003e1,000 hours of qualifying experience\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eUntil the specialty examination is successfully completed, the trainee must work under \u003cstrong\u003e100 percent supervision\u003c\/strong\u003e. Washington provides a modified supervision pathway after successful completion of the specialty examination while the trainee completes the remaining hours required for full certification.\u003c\/p\u003e\n\n\u003cp\u003eThe statutory scope of Equipment Repair involves \u003cstrong\u003eservicing, maintaining, repairing, or replacing utilization equipment\u003c\/strong\u003e or related wiring, appliances, devices, or equipment as permitted by Washington law and rule.\u003c\/p\u003e\n\n\u003cp\u003eFor the 07E specialty, qualifying \u003cstrong\u003eutilization equipment\u003c\/strong\u003e must be self-contained on a single skid or frame and factory built to standardized sizes or types. It must also be listed or field evaluated by an approved laboratory or otherwise approved by the department under applicable Washington rules.\u003c\/p\u003e\n\n\u003cp\u003eThe utilization equipment must be connected as a single unit to a single source of electrical power limited to a maximum of \u003cstrong\u003e600 volts\u003c\/strong\u003e. The equipment may also be connected to a separate single source of electrical control power limited to a maximum of \u003cstrong\u003e250 volts\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eWashington's statutory definition excludes devices used for occupant space heating in industrial, commercial, hospital, educational, public, private commercial, and other covered buildings from the utilization equipment included within this specialty.\u003c\/p\u003e\n\n\u003cp\u003eThe 07E specialty includes the \u003cstrong\u003elike-in-kind replacement of qualifying equipment\u003c\/strong\u003e when the same unmodified electrical circuit is used to supply the replacement equipment.\u003c\/p\u003e\n\n\u003cp\u003eIt also includes like-in-kind replacement or repair of remote control components that are integral to the operation of the qualifying utilization equipment and like-in-kind replacement or repair of electrical components located within the equipment.\u003c\/p\u003e\n\n\u003cp\u003eThe specialty may disconnect, replace, and reconnect low-voltage control wiring and line-voltage supply whips not exceeding \u003cstrong\u003esix feet in length\u003c\/strong\u003e, provided there are no modifications to the characteristics of the branch circuit.\u003c\/p\u003e\n\n\u003cp\u003eThe Equipment Repair specialty does not authorize the installation, repair, or modification of wiring interconnecting equipment and remote components, branch-circuit conductors, services, feeders, panelboards, disconnect switches, motor control centers, remote magnetic starters or contactors, or raceway and conductor systems that interconnect multiple pieces of equipment or other electrical components.\u003c\/p\u003e\n\n\u003cp\u003eThe specialty also does not include work that provides electrical feeds into a power distribution unit or installation of conduits and raceways.\u003c\/p\u003e\n\n\u003cp\u003eElectrical work governed by the NEC articles covering classified hazardous locations is outside the 07E scope, with the statutory exception for qualifying electrical work in sewage pumping stations.\u003c\/p\u003e\n\n\u003cp\u003eWashington rules also specify that the Equipment Repair specialty cannot perform plumbing work regulated under Washington plumbing law.\u003c\/p\u003e\n\n\u003cp\u003eA specialty Master Electrician may work with the tools of the electrical trade within the applicable specialty and may serve as a designated master for an electrical contractor when the contractor's licensing and assignment requirements are satisfied. When assigned to a contractor, the Master Electrician accepts responsibility for helping ensure that the contractor complies with applicable Washington electrical laws and rules.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eReference Books\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRevised Code of Washington (RCW) Chapter 19.28\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThis reference contains Washington electrical statutes governing electricians, Master Electricians, contractors, certification, electrical installations, and Equipment Repair scope. RCW 19.28.095 specifically addresses Equipment Repair work and the definition of qualifying utilization equipment.\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWashington Administrative Code (WAC) Chapter 296-46B\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThis reference contains Washington rules governing specialty classifications, work experience, supervision, examinations, Master Electrician certification, contractors, permits, inspections, and the 07E Equipment Repair specialty.\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNational Electrical Code, NEC, 2020 Edition\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe NEC provides technical requirements for wiring and protection, overcurrent protection, grounding and bonding, wiring methods, electrical equipment, motors, hazardous locations, special occupancies, special conditions, and related electrical work.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eCandidates should study all three references as a coordinated set. Technical installation and equipment questions generally require NEC knowledge, while the legal scope of Equipment Repair work, Master Electrician eligibility, and Washington certification requirements require familiarity with RCW Chapter 19.28 and WAC Chapter 296-46B.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eExam Room Approved Books\u003c\/h2\u003e\n\n\u003cul\u003e\n  \u003cli\u003e\n\u003cstrong\u003eNational Electrical Code, NEC, 2020 Edition\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003eThe 2020 NEC is permitted during Washington electrical examinations. Permanent index tabs, highlighting, and underlining are allowed under applicable examination rules, while handwritten notes, removable tabs, and sticky notes are prohibited.\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eRevised Code of Washington (RCW) Chapter 19.28\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003ePrinted copies of Washington electrical law may be used during testing when prepared according to Labor \u0026amp; Industries examination requirements.\u003c\/span\u003e\n\u003c\/li\u003e\n  \u003cli\u003e\n\u003cstrong\u003eWashington Administrative Code (WAC) Chapter 296-46B\u003c\/strong\u003e\u003cbr\u003e\u003cspan\u003ePrinted copies of Washington electrical rules may be used during the examination when prepared according to the applicable testing requirements.\u003c\/span\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003ePreparing with the same references that will be available during the examination can help candidates become comfortable with article organization, definitions, tables, specialty provisions, and Washington Equipment Repair requirements.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eTest Information and Study Materials\u003c\/h2\u003e\n\n\u003cp\u003e\u003cstrong\u003eWiring Methods:\u003c\/strong\u003e Wiring methods represent one of the larger knowledge areas on the 07E Master Electrician examination. Review raceways, cables, conductors, boxes, fittings, flexible connections, support requirements, protection, and equipment wiring methods.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eOvercurrent Protection:\u003c\/strong\u003e Study circuit breakers, fuses, equipment protection, conductor protection, branch-circuit ratings, and overcurrent requirements affecting utilization equipment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGrounding and Bonding:\u003c\/strong\u003e Review grounding and bonding of equipment, equipment grounding conductors, enclosures, continuity, grounding methods, and related requirements for equipment supplied at different voltage levels.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMotors and Related Equipment:\u003c\/strong\u003e Equipment Repair work frequently involves motor-driven utilization equipment. Review motors, motor controllers, overload protection, disconnecting means, generators, transformers, and related equipment requirements.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eElectrical Equipment:\u003c\/strong\u003e Study requirements involving flexible cords, switches, receptacles, disconnecting means, equipment wiring, transformers, capacitors, storage batteries, and other electrical components associated with utilization equipment.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eHazardous Locations:\u003c\/strong\u003e The examination includes hazardous-location knowledge. The 07E specialty generally excludes work governed by the identified classified-location NEC articles, except for the statutory exception involving qualifying sewage pumping station work.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eSpecial Occupancies and Special Conditions:\u003c\/strong\u003e Review applicable NEC requirements for specialized occupancies and conditions that may affect equipment installations and maintenance work.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eGeneral Trade Knowledge and Theory:\u003c\/strong\u003e Practice voltage, current, resistance, power, Ohm's law, series and parallel circuits, motor calculations, basic electrical troubleshooting, and other trade calculations.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003e07E Utilization Equipment Definition:\u003c\/strong\u003e Know the requirements that equipment be self-contained on a single skid or frame, factory built to standardized sizes or types, appropriately listed, evaluated, or approved, and connected as a single unit to a qualifying source of power.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eVoltage Limits:\u003c\/strong\u003e Remember that qualifying utilization equipment may be connected to a single power source up to 600 volts and a separate control-power source up to 250 volts.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003ePermitted Repair Work:\u003c\/strong\u003e Review like-in-kind equipment replacement, internal component replacement or repair, integral remote-control component work, and the six-foot supply-whip allowance.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eExcluded Work:\u003c\/strong\u003e Understand the limits on branch-circuit conductors, feeders, services, panelboards, disconnect switches, motor control centers, remote starters and contactors, interconnecting wiring, conduits, raceways, and classified-location work.\u003c\/p\u003e\n\n\u003cp\u003e\u003cstrong\u003eMaster Electrician Responsibilities:\u003c\/strong\u003e Study eligibility, contractor assignment, certification, examinations, permits, inspections, and the compliance responsibilities associated with serving as a designated specialty Master Electrician.\u003c\/p\u003e\n\n\u003cp\u003eA useful study method is to identify the type of question before beginning a reference lookup. A question about grounding, motors, or wiring methods will generally point toward the NEC. A question about what an Equipment Repair electrician may legally perform will often require RCW 19.28.095 or WAC Chapter 296-46B.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eHow 1 Exam Prep Helps You Reach Your Goal\u003c\/h2\u003e\n\n\u003cp\u003e1 Exam Prep helps Washington Equipment Repair Master Electrician candidates organize preparation around the three core references included in this package: the \u003cstrong\u003e2020 National Electrical Code\u003c\/strong\u003e, \u003cstrong\u003eRCW Chapter 19.28\u003c\/strong\u003e, and \u003cstrong\u003eWAC Chapter 296-46B\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003cp\u003eThe package supports trade-focused review of wiring methods, overcurrent protection, grounding and bonding, electrical equipment, motors, electrical theory, specialty scope, Master Electrician responsibilities, and Washington electrical laws and rules.\u003c\/p\u003e\n\n\u003cp\u003e1 Exam Prep encourages practice-oriented preparation for an open-book testing environment. Candidates can strengthen reference-navigation skills by identifying the subject of each question, selecting the appropriate reference, locating the controlling provision, and applying it efficiently.\u003c\/p\u003e\n\n\u003cp\u003eExperienced equipment-repair electricians often bring significant practical troubleshooting, motor, equipment, and maintenance knowledge to the examination. Structured preparation helps connect that field experience with the precise NEC and Washington requirements used to regulate the work.\u003c\/p\u003e\n\n\u003cp\u003eWashington-specific study is especially important for 07E because the specialty depends on a detailed statutory definition of utilization equipment. Understanding what equipment qualifies, what voltage limitations apply, which repair activities are permitted, and which building-wiring activities remain outside the scope can strengthen preparation for the Washington Codes section.\u003c\/p\u003e\n\n\u003cp\u003eThe goal is to combine practical Equipment Repair experience with organized code study, reference-navigation practice, trade-focused review, and a stronger understanding of Washington electrical requirements. This Washington Equipment Repair Master Electrician 07E Book Package provides the core reference materials needed to support that preparation.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eFrequently Asked Questions\u003c\/h2\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eWhat is the official Washington classification for Equipment Repair?\u003c\/h2\u003e\n\n\u003cp\u003eWashington identifies Equipment Repair as electrical specialty classification \u003cstrong\u003e07E\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eWhat books are included in this package?\u003c\/h2\u003e\n\n\u003cp\u003eThis package includes \u003cstrong\u003eRCW Chapter 19.28\u003c\/strong\u003e, \u003cstrong\u003eWAC Chapter 296-46B\u003c\/strong\u003e, and the \u003cstrong\u003e2020 National Electrical Code\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eIs the Washington 07E Master Electrician examination open book?\u003c\/h2\u003e\n\n\u003cp\u003eYes. Washington electrical examinations are open book under the applicable testing rules.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eHow many questions are on the 07E Master Electrician examination?\u003c\/h2\u003e\n\n\u003cp\u003eThe published examination outline lists approximately \u003cstrong\u003e34 NEC \u0026amp; Theory questions\u003c\/strong\u003e and \u003cstrong\u003e20 Washington Codes questions\u003c\/strong\u003e, for approximately 54 questions total.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eHow much testing time is allowed?\u003c\/h2\u003e\n\n\u003cp\u003eThe NEC \u0026amp; Theory section allows approximately 2 hours, and the Washington Codes section allows approximately 1 hour.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eWhat score is required to pass?\u003c\/h2\u003e\n\n\u003cp\u003eWashington requires a score of at least \u003cstrong\u003e70%\u003c\/strong\u003e on each required examination section.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eHow long must I hold the 07E Electrician certificate before taking the Master examination?\u003c\/h2\u003e\n\n\u003cp\u003eAn applicant for the specialty Master Electrician examination must have possessed a valid Washington specialty electrician certificate in the applicable specialty for at least \u003cstrong\u003etwo years\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eHow much experience is required for full 07E Electrician certification?\u003c\/h2\u003e\n\n\u003cp\u003eFull Washington 07E Equipment Repair Electrician certification requires \u003cstrong\u003e2,000 hours of qualifying work experience\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eWhen can a 07E trainee become eligible for the specialty electrician examination?\u003c\/h2\u003e\n\n\u003cp\u003eA trainee may become eligible for the 07E examination after completing at least \u003cstrong\u003e1,000 hours of qualifying work experience\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eWhat supervision applies before passing the 07E examination?\u003c\/h2\u003e\n\n\u003cp\u003eThe trainee must remain under \u003cstrong\u003e100 percent supervision\u003c\/strong\u003e until successfully completing the applicable specialty examination.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eWhat voltage limit applies to qualifying 07E utilization equipment?\u003c\/h2\u003e\n\n\u003cp\u003eQualifying utilization equipment may be connected as a single unit to a single electrical power source limited to a maximum of \u003cstrong\u003e600 volts\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eCan 07E equipment have a separate control-power source?\u003c\/h2\u003e\n\n\u003cp\u003eYes. Qualifying equipment may also be connected to a separate single source of electrical control power limited to a maximum of \u003cstrong\u003e250 volts\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eCan a 07E Electrician replace qualifying equipment?\u003c\/h2\u003e\n\n\u003cp\u003eYes. The specialty permits like-in-kind replacement of qualifying utilization equipment when the same unmodified electrical circuit supplies the replacement.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eCan a 07E Electrician repair components inside the equipment?\u003c\/h2\u003e\n\n\u003cp\u003eYes. The scope includes like-in-kind replacement or repair of electrical components within qualifying utilization equipment and qualifying integral remote-control components.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eCan a 07E Electrician reconnect supply whips?\u003c\/h2\u003e\n\n\u003cp\u003eYes. The specialty permits disconnection, replacement, and reconnection of qualifying low-voltage control and line-voltage supply whips not exceeding \u003cstrong\u003esix feet\u003c\/strong\u003e when branch-circuit characteristics are not modified.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eCan a 07E Electrician install new feeders or branch circuits?\u003c\/h2\u003e\n\n\u003cp\u003eNo. The Equipment Repair specialty does not authorize installation, repair, or modification of services, feeders, branch-circuit conductors, panelboards, disconnect switches, motor control centers, or other excluded building-wiring systems.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eCan a 07E Electrician install conduit or raceway systems?\u003c\/h2\u003e\n\n\u003cp\u003eThe 07E scope does not include installation of conduits and raceways or work providing electrical feeds into a power distribution unit.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eCan I use the 2020 NEC during the examination?\u003c\/h2\u003e\n\n\u003cp\u003eYes. The Washington electrical examination program covered by this package permits the \u003cstrong\u003e2020 National Electrical Code\u003c\/strong\u003e.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eCan I bring RCW 19.28 and WAC 296-46B into the examination?\u003c\/h2\u003e\n\n\u003cp\u003eYes. Printed copies of both Washington electrical references may be used when prepared according to Labor \u0026amp; Industries examination requirements.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eWho administers the Washington 07E Master Electrician examination?\u003c\/h2\u003e\n\n\u003cp\u003eWashington electrical examinations are administered through \u003cstrong\u003ePSI\u003c\/strong\u003e after the applicable examination approval through Washington Labor \u0026amp; Industries.\u003c\/p\u003e\n\n\u003ch2 style=\"color: #d32f2f;\"\u003eWhat should I focus on while studying?\u003c\/h2\u003e\n\n\u003cp\u003eFocus on wiring methods, overcurrent protection, grounding and bonding, motors, electrical equipment, general electrical theory, the statutory definition of utilization equipment, 07E scope limitations, Master Electrician responsibilities, and Washington electrical laws and rules.\u003c\/p\u003e\n\n","brand":"1 Exam Prep","offers":[{"title":"Default Title","offer_id":46541683392569,"sku":null,"price":295.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1789\/0861\/files\/WA-EQUIPMENTMASTERELECTRICIAN-BOOKS.jpg?v=1789756908","url":"https:\/\/1examprep.com\/products\/washington-equipment-repair-master-electrician-07e-book-package","provider":"1 Exam Prep","version":"1.0","type":"link"}