• 2021 International Residential Code

    2021 International Residential Code

    • $187.00
    Shipping calculated at checkout.

    Call to ask about financial assistance

    100% safasfaction

    This comprehensive code comprises all building, plumbing, mechanical, fuel gas and electrical requirements for one- and two-family dwellings and townhouses up to three stories. The 2021 IRC® contains many important changes such as:

    • Braced wall lines must be placed on a physical wall or placed between multiple walls.
    • The rated separation for two-family dwellings is 1 hour whether or not a lot line exists between units.
    • Emergency escape and rescue openings require a clear 36-inch-wide path to a public way.
    • An engineered design is required for storm shelters.
    • A habitable attic is limited to one-half the area of the story below and the dwelling requires sprinklers.
    • Updated Wind Speed maps match IBC and ASCE 7 maps.
    • Deck design now considers snow load, tributary area for footing and post height, and guard details.
    • Specific requirements for deck guardrails were added.
    • Component and cladding wind pressures in Table R301.2(2) are updated for new design wind speeds and hip or gable roof profiles.
    • Minimum footing size tables are revised to more accurately reflect current practice.
    • Cripple wall requirements apply only to exterior cripple walls.
    • New appendices for cob construction and 3D printed construction are added.
    • A 30 percent reduction of airflow is permitted for balanced ventilation systems.
    • Commercial gas cooking appliances are prohibited.
    • The head pressure for a water test of DWV systems increased to 10 feet.
    • Air vacuum testing is now permitted for plastic piping DWV systems.
    • Section P2904 for dwelling sprinklers is expanded to more closely align with NFPA 13D.
    • An emergency service disconnect is required in a readily accessible outdoor location.
    • A surge-protective device (SPD) is now required at the service panel.
    • The number of receptacle outlets required for peninsular and island countertops in kitchens is determined by the area of the countertop surface.
    • GFCI protection is now required for damp and wet locations not included in the other 10 areas requiring GFCI protection.

    We Also Recommend