Prepare for the Connecticut Limited Gas and Oil Burner Contractor (B-1) examination with a coordinated collection of mechanical, residential, fuel-gas, oil-burning, natural-gas, liquefied petroleum gas, and burner-service references. This package combines the six books identified for use during the open-book trade examination with an additional oil-burner study reference.
The Connecticut B-1 examination evaluates knowledge of gas and oil burner installation, service, repair, replacement, alteration, and maintenance in domestic and light commercial applications. Candidates must understand burners, fuel piping, controls, equipment, chimneys, flues, vents, natural gas, liquefied petroleum gas, testing procedures, and safe work practices.
This package includes the International Mechanical Code, 2021, International Residential Code for One- and Two-Family Dwellings, 2021, International Fuel Gas Code, 2018, NFPA 31: Standard for the Installation of Oil-Burning Equipment, 2011, NFPA 54: National Fuel Gas Code Handbook, 2012, and NFPA 58: Liquefied Petroleum Gas Code, 2014.
The package also includes Residential Oil Burners, 3rd Edition. This additional study reference supports preparation involving burner components, fuel delivery, ignition, combustion, draft, nozzles, pumps, controls, testing instruments, maintenance, and troubleshooting. It is recommended for study but is not identified as an exam-room reference.
The Connecticut B-1 trade examination is open book and timed. Candidates need more than access to the required codes and standards. They should understand the purpose of each book, become familiar with its chapters and indexes, and practice locating requirements without searching every reference for every question.
This package is designed for experienced burner technicians, heating professionals, licensed journeypersons, fuel-gas installers, oil-heating technicians, service professionals, and qualified applicants pursuing the Connecticut B-1 contractor credential.
This product contains the listed exam and study books. Online course access, highlighting and tabbing, Application Service, examination registration, Business and Law materials, government fees, book rental, and professional licensing approval are not identified as included.
The Connecticut B-1 Limited Gas and Oil Burner Contractor trade examination contains 50 questions. Candidates receive two hours to complete the test and must earn a minimum score of 70 percent.
The published examination content outline includes:
Fuel-gas systems are the largest individual examination category. Candidates should study gas-piping materials, sizing, pressure, regulators, appliance connections, shutoff valves, sediment traps, testing, purging, combustion air, venting, and equipment installation.
Natural-gas and liquefied petroleum gas questions may address the characteristics of each fuel, system pressure, regulator arrangements, piping, containers, separation distances, appliance requirements, leak testing, safety devices, and proper installation practices.
Oil-burner questions may involve fuel storage, oil-supply piping, filters, pumps, nozzles, burner motors, ignition components, combustion, draft, flame characteristics, burner adjustment, venting, controls, and maintenance. Candidates should understand how nozzle size, spray pattern, pump pressure, combustion air, ignition, and draft affect burner performance.
General-knowledge questions may cover heat, combustion, tools, materials, equipment operation, electrical principles, burner components, safety, and common trade terminology. Candidates should recognize how fuel, air, ignition, draft, and venting work together during safe burner operation.
Control questions may involve thermostats, transformers, relays, primary controls, limit switches, safety controls, flame-safeguard devices, gas valves, burner motors, and ignition systems. Candidates should understand the purpose of each control and the sequence in which burner components operate.
Equipment questions may address furnaces, boilers, burners, fuel tanks, regulators, valves, combustion chambers, heat exchangers, venting systems, and related accessories. Preparation should include installation clearances, access, service requirements, and equipment safety.
Piping and valve questions may involve approved materials, sizing, supports, fittings, joining methods, shutoff valves, pressure regulators, oil-supply lines, gas piping, and equipment connections. Improper materials or installation methods can cause leakage, inadequate fuel delivery, poor combustion, or unsafe equipment operation.
Testing and maintenance questions may include leak testing, combustion testing, draft measurement, smoke testing, carbon dioxide or oxygen readings, carbon monoxide awareness, inspection, cleaning, troubleshooting, startup, shutdown, and verification of safe operation.
The Connecticut Limited Gas and Oil Burner Contractor (B-1) trade examination is an open-book test. Candidates are responsible for bringing their own approved references to the testing center.
The two-hour time limit provides an average of approximately two minutes and twenty-four seconds per question. Candidates who are unfamiliar with the books may lose valuable time deciding where to search. Preparation should include repeated practice with each reference under timed conditions.
Reference books may be highlighted, underlined, annotated, or indexed before the examination. Permanent tabs are permitted. Temporary tabs, including removable or repositionable notes, are not allowed.
Candidates may not write in the books during the examination. Loose papers and unauthorized attached materials are prohibited. Questions and answers written into the references must be removed before entering the examination room.
A silent, nonprinting, non-programmable calculator may be used. Candidates should practice using an approved calculator for gas-pipe sizing and other trade calculations.
The International Mechanical Code supports questions involving mechanical equipment, appliance installation, combustion air, chimneys, vents, fuel systems, clearances, access, and safety. The International Residential Code addresses residential mechanical and fuel-gas requirements for one- and two-family dwellings.
The International Fuel Gas Code supports preparation involving gas-piping systems, appliance connections, pressure regulators, combustion air, venting, testing, purging, and fuel-gas equipment. NFPA 54 provides additional natural-gas requirements and detailed guidance for gas installations.
NFPA 31 covers oil-burning equipment, tanks, fuel piping, burners, controls, combustion air, venting, and related installation requirements. NFPA 58 covers liquefied petroleum gas containers, regulators, piping, equipment, separation distances, installation, operation, storage, and safety.
For gas-pipe sizing questions, candidates must use the longest-length method. Practice identifying the total connected load, measuring the longest developed piping length, choosing the correct pressure and material table, and selecting a pipe size with sufficient capacity.
Develop a consistent reference-search method. Identify the principal subject, select the most relevant code or standard, use the index or table of contents, and read the complete applicable provision. Review definitions, exceptions, table headings, notes, and related sections before selecting an answer.
The Connecticut Department of Consumer Protection regulates occupational trade licenses and determines examination eligibility. PSI administers the examination after the state approves the applicant.
The B-1 trade examination and the contractor Business and Law examination are separate requirements. Passing the trade test does not replace the Business and Law examination.
This exam book package does not include the Business and Law reference, Application Service, application preparation, examination registration, government charges, or submission of licensing documents.
The Connecticut B-1 Limited Gas and Oil Burner Contractor license permits the installation, repair, replacement, alteration, and maintenance of gas or oil burners for domestic and light commercial installations.
For this classification, a domestic or light commercial burner is one consuming five gallons of fuel or less per hour or serving a system with a total heating load not exceeding 500,000 BTUs.
The license permits piping for petroleum-based fuels and alternative fuels, including tanks and related equipment. It also includes liquefied petroleum gas supplied by containers, natural-gas piping, approved gas applications, gas-utilization equipment, and accessories within the license scope.
The B-1 classification includes sheet-metal work when that work pertains to the limitations of the credential. The license does not create unlimited authority for mechanical, heating, cooling, plumbing, or fuel work outside the defined B-1 scope.
Applicants must document two years as a properly licensed journeyperson or demonstrate equivalent experience and training accepted by the Connecticut Department of Consumer Protection.
Applicants relying on equivalent training, experience, or an out-of-state credential must provide sufficient documentation for the state to compare their qualifications with Connecticut requirements. Prior employment or licensing in another jurisdiction does not automatically establish eligibility.
PSI administers the examinations but does not decide whether an applicant qualifies for the license. The Department of Consumer Protection reviews the application and authorizes eligible candidates to test.
After passing the trade and Business and Law examinations, the applicant must complete the remaining licensing requirements and submit the applicable state charges. Passing the examinations alone does not authorize contracting work.
The individual B-1 license is separate from business registration, tax accounts, insurance, permits, and other company-level requirements. Additional registrations may apply depending on the business structure and services offered.
Residential Oil Burners, 3rd Edition is included for preparation but is not identified as a book permitted in the examination room.
Build a study schedule around the ten published examination categories. Give substantial attention to fuel-gas systems, oil burners, natural gas, and liquefied petroleum gas because these areas account for a large portion of the test.
Create a reference map showing which book supports each subject. Use the International Fuel Gas Code and NFPA 54 for gas-system questions, NFPA 58 for LP-gas topics, and NFPA 31 for oil-burning equipment.
Practice gas-pipe sizing with the longest-length method. Review connected appliance loads, developed piping length, operating pressure, material type, table selection, and minimum pipe capacity.
For oil burners, study fuel tanks, piping, filters, pumps, nozzles, ignition, electrodes, combustion air, draft, venting, controls, testing, and maintenance. Use Residential Oil Burners to strengthen practical understanding before switching to exam-room references for timed practice.
Review control sequences and safety devices. Understand how thermostats, primary controls, flame detection, ignition components, motors, valves, limits, and emergency switches interact during burner startup, operation, and shutdown.
Complete timed practice sessions using only the six books allowed into the examination. Answer familiar questions first, mark lengthy code searches, and return to difficult questions after completing the remaining items.
1 Exam Prep helps Connecticut B-1 candidates organize the references needed for open-book contractor examination preparation. This package combines the six exam-room books with an additional oil-burner study reference.
The books support trade-focused review of fuel-gas systems, oil burners, natural gas, liquefied petroleum gas, controls, equipment, piping, valves, chimneys, vents, testing, maintenance, and general burner knowledge.
An organized study approach makes a multi-book examination easier to manage. Candidates can review one topic at a time, identify the most useful reference, locate supporting requirements, and return to the books when reviewing missed practice questions.
Reference-navigation practice is especially important during a two-hour open-book examination. Familiarity with chapters, indexes, definitions, tables, and code organization can help candidates use their testing time more effectively.
This package does not guarantee a passing score, examination eligibility, state approval, or license issuance. Results depend on the candidate’s qualifications, experience, technical knowledge, preparation, reference familiarity, and examination performance.
The package includes seven books covering mechanical requirements, residential systems, fuel gas, oil-burning equipment, natural gas, LP gas, and residential oil-burner service.
Yes. The Connecticut B-1 Limited Gas and Oil Burner Contractor trade examination is open book.
The examination contains 50 questions and allows two hours for completion.
A minimum score of 70 percent is required.
No. Six books are identified for exam-room use. Residential Oil Burners, 3rd Edition is an additional study reference and is not identified as allowed in the examination room.
The references may be highlighted, underlined, annotated, or indexed before testing. Permanent tabs are permitted, but temporary tabs are not allowed.
Yes. Connecticut requires contractor applicants to pass the applicable trade examination and the Business and Law examination.
The license covers qualifying gas and oil burner installation, repair, replacement, alteration, and maintenance for domestic and light commercial applications within Connecticut’s stated fuel-consumption and heating-load limits.
Applicants must document two years as a properly licensed journeyperson or equivalent experience and training accepted by Connecticut.
No. Application Service is not identified as included with this exam book package.
No. State application fees, PSI testing charges, licensing fees, and other third-party costs are not included.
No. Connecticut determines eligibility based on the applicant’s experience, licensing history, training, and supporting documentation.
No. Passing the required examinations is one part of the licensing process. The applicant must complete all remaining Connecticut requirements before the license can be issued.