Nevada Carpentry, Maintenance, And Minor Repairs Contractor (C-3) Highlighted & Tabbed Book Package

Nevada Carpentry, Maintenance, And Minor Repairs Contractor (C-3) Highlighted & Tabbed Book Package

Regular price $795.00
Sale price $795.00 Regular price $995.00
Sale Sold out
Shipping calculated at checkout.
Choose Your Option

CALL TO ASK ABOUT FINANCIAL ASSISTANCE

  • image-right
Customer Reviews
View full details

Nevada Carpentry, Maintenance, And Minor Repairs Contractor (C-3) Highlighted & Tabbed Book Package

Prepare for the Nevada Carpentry, Maintenance, and Minor Repairs Contractor (C-3) examination with a complete highlighted and tabbed book package designed around the technical subjects and reference materials used for C-3 preparation. This package combines the approved exam-room code book with study references covering carpentry, structural framing, wood trusses, drywall and gypsum systems, finish carpentry, construction safety, maintenance, and repair-related knowledge.

The Nevada C-3 Carpentry, Maintenance, and Minor Repairs classification covers a broad range of construction work. Candidates preparing for the full C-3 classification should expect to study more than basic framing or general carpentry. Preparation can include rough carpentry, finish work, structural components, doors and windows, truss systems, drywall, maintenance activities, repair procedures, safety, and applicable building-code requirements.

The International Building Code, 2018 is the approved reference used during the Nevada C-3 trade examination. Because the test is open book, candidates should become familiar with the organization of the IBC and practice locating relevant requirements before exam day. The remaining books in this package support technical study but are not allowed into the C-3 trade examination.

All books in this package are highlighted and tabbed. The organized format helps candidates identify important material, move between topics more efficiently, and develop a structured preparation routine. Highlighting and tabs are particularly useful when repeatedly working through the International Building Code and studying technical subjects across several different references.

This package includes material for general construction safety, broad carpentry fundamentals, truss handling and bracing, gypsum construction, and finish carpentry. Together, these resources provide a comprehensive study foundation for candidates preparing for the full C-3 examination.

Please allow up to 15 business days for tabbed and highlighted book package orders.

What You Get

  • International Building Code, 2018 — highlighted and tabbed; approved for use during the C-3 trade examination.
  • Code of Federal Regulations - 29 CFR Part 1926 (OSHA) — highlighted and tabbed study reference.
  • Carpentry and Building Construction, 2016 — highlighted and tabbed study reference.
  • BCSI: Guide to Good Practice for Handling, Installing, Restraining, and Bracing of Metal Plate Connected Wood Trusses, 2025 — highlighted and tabbed study reference.
  • Gypsum Construction Handbook, 7th edition — highlighted and tabbed study reference.
  • Finish Carpenter's Manual, Jim Tolpin, 1993 — highlighted and tabbed study reference.

Exam Details

The Nevada C-3 Carpentry, Maintenance, and Minor Repairs trade examination is administered through PSI for candidates authorized to test through the Nevada State Contractors Board.

  • Exam: Nevada C-3 Carpentry, Maintenance, and Minor Repairs
  • Testing Provider: PSI
  • Number of Questions: 56
  • Time Allowed: 120 minutes
  • Minimum Passing Score: 40 correct answers

The full C-3 classification incorporates several related areas of carpentry, maintenance, and minor repair work. Candidates should prepare for a broad technical range rather than concentrating on only one area of construction.

Study should include framing systems, floors, walls, roofs, sheathing, structural components, wood trusses, doors and windows, finish carpentry, drywall and gypsum systems, maintenance, repair procedures, materials, tools, measurements, safety, and building-code navigation.

Because the examination contains 56 questions to be completed in two hours, pacing is important. Candidates should practice recognizing which questions can be answered directly from trade knowledge and which require a lookup in the International Building Code.

Repeated navigation practice can reduce the amount of time spent searching during the exam. Candidates should become comfortable with the IBC chapter structure, definitions, tables, index, exceptions, and cross-references before test day.

Open Book Test

The Nevada C-3 Carpentry, Maintenance, and Minor Repairs examination is an open-book test. The approved exam-room reference included in this highlighted and tabbed package is:

  • International Building Code, 2018

Candidates should use the International Building Code throughout preparation and practice locating requirements connected with framing, structural construction, exterior walls, roof assemblies, openings, stairs, guards, doors, windows, and other building topics relevant to C-3 work.

The highlighted and tabbed format supports faster study and repeated navigation practice. Candidates can become familiar with the location of important code subjects before they enter the testing center instead of relying on a completely unfamiliar reference.

The following books in this package are not allowed into the C-3 trade examination:

  • Code of Federal Regulations - 29 CFR Part 1926 (OSHA)
  • Carpentry and Building Construction, 2016
  • BCSI: Guide to Good Practice for Handling, Installing, Restraining, and Bracing of Metal Plate Connected Wood Trusses, 2025
  • Gypsum Construction Handbook, 7th edition
  • Finish Carpenter's Manual, Jim Tolpin, 1993

These study-only references are included because the C-3 exam requires technical knowledge beyond code navigation. Candidates should use them to build understanding before test day and be prepared to answer related questions without having those books available during the examination.

A strong open-book strategy combines technical knowledge with selective use of the IBC. Familiar questions should generally be answered directly, while the code book should be used when a precise requirement needs to be confirmed.

Licensing Steps

The Nevada State Contractors Board regulates the C-3 Carpentry, Maintenance, and Minor Repairs classification. Passing the trade examination is one part of the contractor licensing process.

  1. Confirm the C-3 classification. Determine that Carpentry, Maintenance, and Minor Repairs matches the type of contracting work the business intends to perform.
  2. Identify the qualifying individual. Designate the individual who will satisfy the applicable technical experience and examination requirements.
  3. Document qualifying experience. Prepare records demonstrating relevant carpentry, maintenance, repair, and related construction work.
  4. Prepare the Nevada contractor license application. Gather business information, qualifier details, experience documentation, financial information, and required supporting materials.
  5. Submit the application. The Nevada State Contractors Board reviews the applicant's qualifications before establishing examination eligibility.
  6. Complete applicable background requirements. Follow required fingerprint, disclosure, and background procedures.
  7. Meet financial responsibility requirements. Provide the applicable financial information required during the licensing process.
  8. Receive examination eligibility. Qualified applicants can proceed with scheduling after authorization.
  9. Schedule the C-3 examination through PSI. Arrange the trade examination once eligibility has been established.
  10. Prepare for the trade examination. Study framing, carpentry, finish work, trusses, drywall, repairs, maintenance, safety, and IBC navigation.
  11. Prepare for Nevada Business and Law. Nevada contractor applicants generally must also satisfy the applicable management qualification requirement unless an approved waiver applies.
  12. Complete applicable examinations. Meet the required trade and management testing requirements.
  13. Complete remaining licensing requirements. Address applicable bonding, financial responsibility, background, and other Nevada State Contractors Board requirements.

State Requirements

The Nevada C-3 Carpentry, Maintenance, and Minor Repairs classification incorporates several related subclassifications. The full C-3 classification includes work associated with C-3A Carpentry and Repairs, C-3B Finish Carpentry, C-3C Insulation and Weather Stripping, C-3D Overhead Doors, and C-3E Maintenance and Minor Repairs.

Because the full classification includes multiple areas, candidates should prepare for a broader range of trade knowledge than would be required for only one subclassification. Preparation can involve structural carpentry, finish carpentry, insulation and weather-related work, overhead-door concepts, maintenance, repair procedures, and related building systems.

For the standard Nevada contractor licensing pathway, the qualifying individual generally must document at least four years of qualifying experience within the 10 years immediately preceding the application.

Qualifying experience should directly relate to the classification being requested. Applicants should maintain organized records describing the work performed, responsibilities held, and the period during which the experience was obtained.

Nevada contractor licensing also includes management qualification, financial responsibility review, bonding, background procedures, and other requirements administered by the Nevada State Contractors Board. Passing the C-3 trade examination alone does not automatically result in license issuance.

Reference Books

  • International Building Code, 2018
    Highlighted and tabbed approved exam-room reference supporting code study involving framing, structural systems, roofs, exterior walls, openings, stairs, guards, doors, windows, and other building requirements relevant to Nevada C-3 work.
  • Code of Federal Regulations - 29 CFR Part 1926 (OSHA)
    Highlighted and tabbed study reference supporting construction safety preparation, including fall hazards, ladders, scaffolds, tools, personal protective equipment, material handling, and general jobsite safety. This book is not allowed into the C-3 trade examination.
  • Carpentry and Building Construction, 2016
    Highlighted and tabbed study reference supporting framing, floors, walls, roofs, sheathing, doors, windows, siding, tools, materials, measurements, layouts, and general rough and finish carpentry knowledge. This book is not allowed into the C-3 trade examination.
  • BCSI: Guide to Good Practice for Handling, Installing, Restraining, and Bracing of Metal Plate Connected Wood Trusses, 2025
    Highlighted and tabbed study reference covering safe handling, installation, restraint, and bracing practices for metal plate connected wood trusses. This book is not allowed into the C-3 trade examination.
  • Gypsum Construction Handbook, 7th edition
    Highlighted and tabbed study reference supporting drywall and gypsum-system preparation, including materials, installation principles, framing coordination, finishing, and common construction applications. This book is not allowed into the C-3 trade examination.
  • Finish Carpenter's Manual, Jim Tolpin, 1993
    Highlighted and tabbed study reference supporting finish carpentry preparation involving doors, windows, cabinets, trim, millwork, fitting, measurements, tools, and detailed installation methods. This book is not allowed into the C-3 trade examination.

All books in this package are highlighted and tabbed.

Please allow up to 15 business days for tabbed and highlighted book package orders.

Exam Room Approved Books

  • International Building Code, 2018
    This highlighted and tabbed book is the approved reference included for use during the Nevada C-3 Carpentry, Maintenance, and Minor Repairs trade examination.

The remaining included books are study references and are not allowed into the C-3 trade exam. Candidates should use those materials throughout preparation so the technical information can be understood and recalled without reference assistance during testing.

Test Information and Study Materials

A productive C-3 study plan should reflect the broad nature of the classification. Candidates should build a balanced foundation across structural carpentry, finish work, truss systems, drywall, repair activities, safety, and code navigation.

Build broad carpentry knowledge. Use Carpentry and Building Construction to review floors, walls, roofs, framing, sheathing, measurements, layouts, materials, tools, fasteners, doors, windows, siding, and general construction techniques.

Develop finish carpentry skills. Use Finish Carpenter's Manual to reinforce doors, windows, cabinets, trim, millwork, fitting, alignment, measurement, and detail-oriented installation concepts.

Review truss handling and bracing. Use the BCSI guide to study handling, installation, restraint, and bracing principles associated with metal plate connected wood trusses.

Study drywall and gypsum systems. The Gypsum Construction Handbook supports review of materials, installation relationships, finishing concepts, and coordination with framing systems.

Prepare for safety questions. OSHA 29 CFR Part 1926 supports review of ladders, scaffolds, falls, tools, personal protective equipment, and other construction hazards. Because OSHA is not permitted in the trade exam, candidates should learn these concepts before test day.

Practice International Building Code navigation. Work with the IBC repeatedly and practice finding code requirements associated with structural systems, roofs, exterior walls, openings, stairs, guards, doors, windows, and related construction subjects.

Use timed study sessions. With 56 questions in 120 minutes, candidates should develop a steady testing pace and practice deciding whether a code lookup is necessary.

Review weaknesses by topic. Candidates should identify repeated mistakes in framing, finish carpentry, trusses, drywall, safety, repair concepts, or code navigation and devote additional preparation time to those areas.

How 1 Exam Prep Helps You Reach Your Goal

1 Exam Prep supports Nevada C-3 Carpentry, Maintenance, and Minor Repairs Contractor candidates through organized study guidance, trade-focused review, practice-oriented preparation, reference navigation, and confidence-building study structure.

The highlighted and tabbed book package gives candidates an organized set of technical references covering the broad range of subjects associated with the full C-3 classification. Important material is easier to identify during study, allowing candidates to spend more time understanding the content and less time searching through completely unmarked books.

The International Building Code is the approved exam-room reference, so reference-navigation practice should be part of the preparation routine. Repeated use can help candidates recognize where important code topics are located and become more efficient with lookups during the open-book examination.

The study-only books provide technical depth beyond the IBC. Carpentry and Building Construction reinforces general trade knowledge, the BCSI guide supports truss preparation, the Gypsum Construction Handbook strengthens drywall study, Finish Carpenter's Manual focuses on detailed finish work, and OSHA supports jobsite safety preparation.

Practice-oriented preparation can help candidates identify which areas deserve additional study. Someone with extensive framing experience may need more work with finish carpentry, drywall, or code navigation, while another candidate may need additional truss, safety, maintenance, or repair review.

By combining highlighted and tabbed references, trade-focused study, code navigation, and structured review, 1 Exam Prep helps candidates create a more organized approach to preparing for the Nevada C-3 Carpentry, Maintenance, and Minor Repairs Contractor examination.

Frequently Asked Questions

What books are included in the Nevada C-3 Highlighted & Tabbed Book Package?

The package includes the International Building Code, 2018; OSHA 29 CFR Part 1926; Carpentry and Building Construction, 2016; the 2025 BCSI wood truss guide; Gypsum Construction Handbook, 7th edition; and Finish Carpenter's Manual by Jim Tolpin, 1993.

Are all included books highlighted and tabbed?

Yes. All books in this package are highlighted and tabbed.

Which book is allowed into the Nevada C-3 trade examination?

The International Building Code, 2018 is the approved exam-room reference included in this package.

Which books are not allowed into the C-3 exam?

OSHA 29 CFR Part 1926, Carpentry and Building Construction, the BCSI truss guide, Gypsum Construction Handbook, and Finish Carpenter's Manual are study references and are not allowed into the C-3 trade examination.

Is the Nevada C-3 examination open book?

Yes. The Nevada C-3 Carpentry, Maintenance, and Minor Repairs examination is an open-book test using the approved International Building Code reference.

How many questions are on the Nevada C-3 exam?

The examination contains 56 questions.

How much time is allowed for the C-3 exam?

Candidates have 120 minutes to complete the examination.

What score is required to pass?

The minimum passing score is 40 correct answers out of 56 questions.

Why are books included if they cannot be taken into the exam?

The study-only references support technical knowledge in carpentry, truss systems, gypsum construction, finish carpentry, and safety that candidates should understand before test day.

Why should I practice using the International Building Code?

Repeated code-navigation practice helps candidates become familiar with the IBC and locate relevant requirements more efficiently during the timed open-book examination.

Does the C-3 classification cover multiple types of work?

Yes. The full C-3 classification incorporates multiple carpentry, maintenance, and minor repair areas, making broad technical preparation important.

How much qualifying experience is generally required?

For the standard Nevada licensing pathway, the qualifying individual generally must document at least four years of qualifying experience within the 10 years immediately preceding the application.

How long should I allow for the highlighted and tabbed book package order?

Please allow up to 15 business days for tabbed and highlighted book package orders.