ICC Commercial Plumbing Inspector - P2 Exam Prep Guide

The ICC Commercial Plumbing Inspector - P2 examination is designed for plumbing inspectors, building department personnel, code officials, commercial plumbers, plans examiners, contractors, and other professionals responsible for evaluating commercial plumbing installations.

The examination covers fixtures, accessibility, water heaters, potable and nonpotable water systems, sanitary drainage, vents, traps, interceptors, separators, storm drainage, fuel-gas systems, special piping, health care plumbing, inspection procedures, and code-compliant installation practices.

The ICC Commercial Plumbing Inspector - P2 exam prep collection includes online exam preparation, a books and courses rental package, professionally highlighted and tabbed references, and a complete exam book package.

Available P2 Exam Prep Packages

  • ICC Commercial Plumbing Inspector - P2 - Online Exam Prep: $295.00 sale price, reduced from $395.00
  • ICC Commercial Plumbing Inspector - P2 - Books & Courses Rental Package: $940.00 sale price, reduced from $1,240.00
  • ICC Commercial Plumbing Inspector - P2 Highlighted & Tabbed Book Package: $645.00 sale price, reduced from $845.00
  • ICC Commercial Plumbing Inspector - P2 Exam Book Package: $395.00 sale price, reduced from $495.00

The online course supports candidates who already own the correct references. The rental package combines temporary book access with structured training. The highlighted and tabbed package supports faster code navigation, while the exam book package provides permanent ownership of the listed references.

Online Exam Prep

The ICC Commercial Plumbing Inspector - P2 Online Exam Prep course provides flexible, self-paced preparation for candidates who already own the correct code references or plan to obtain them separately.

The course is listed at a sale price of $295.00, reduced from the regular price of $395.00.

Online preparation may help candidates:

  • Review commercial plumbing subjects in a structured order
  • Practice navigating multiple references
  • Apply code provisions to inspection scenarios
  • Review accessibility requirements for plumbing fixtures
  • Practice water supply and drainage calculations
  • Study fuel-gas piping and water heater requirements
  • Complete exam-style practice questions
  • Build speed for timed open-book testing

The course is most effective when candidates work directly from the same code editions used for their scheduled examination.

Books & Courses Rental Package

The ICC Commercial Plumbing Inspector - P2 Books & Courses Rental Package combines temporary access to the listed references with structured online exam preparation.

The package is listed at a sale price of $940.00, reduced from the regular price of $1,240.00.

This package may be suitable for candidates who:

  • Need the exam references and online course together
  • Do not currently own the listed books
  • Want an organized commercial plumbing study plan
  • Need help using code tables and accessibility provisions
  • Want practice with inspection-based questions
  • Prefer temporary book access rather than permanent ownership

Candidates should review the current product page for rental duration, course-access terms, shipping information, deposit requirements, and book-return instructions.

Highlighted & Tabbed Book Package

The ICC Commercial Plumbing Inspector - P2 Highlighted & Tabbed Book Package provides professionally organized references for candidates who want to begin studying without identifying and marking every important section themselves.

The package is listed at a sale price of $645.00, reduced from the regular price of $845.00.

The prepared references may help candidates locate:

  • General plumbing requirements
  • Commercial fixture provisions
  • Accessible plumbing fixture requirements
  • Water heater and fuel-gas provisions
  • Water supply and distribution tables
  • Sanitary drainage and venting requirements
  • Trap, interceptor, and separator provisions
  • Storm drainage and health care plumbing requirements

Highlights and tabs can improve navigation speed, but candidates must still understand definitions, exceptions, diagrams, table notes, and cross-references.

Exam Book Package

The ICC Commercial Plumbing Inspector - P2 Exam Book Package provides the printed references associated with the current preparation collection.

The package is listed at a sale price of $395.00, reduced from the regular price of $495.00.

This option may be appropriate for candidates who:

  • Prefer independent book-based preparation
  • Want permanent ownership of the references
  • Already have commercial plumbing experience
  • Want to create a personalized highlighting system
  • Already have separate training or practice exams
  • Need the books for continued inspection work

What Is the ICC P2 Examination?

The P2 examination is the ICC Commercial Plumbing Inspector national certification exam. It evaluates a candidate’s ability to inspect commercial plumbing and related fuel-gas systems for compliance with applicable code requirements.

Current official examination information lists:

  • 60 examination questions
  • Two-hour-and-30-minute time limit
  • Open-book format for the current package
  • Scaled passing score of 75

A scaled score of 75 is not the same as answering exactly 75% of the questions correctly. ICC uses scaled scoring to maintain a consistent passing standard across different versions of certification exams.

Candidates should verify the selected code year, testing method, approved references, and exam-day rules in the current ICC Exam Catalog before registering.

P2 Exam References

The current 2021 P2 package identifies the following references:

  • International Plumbing Code, 2021 Edition
  • International Fuel Gas Code, 2021 Edition
  • ICC A117.1-2017 Accessible and Usable Buildings and Facilities

The International Plumbing Code supports preparation involving fixtures, water supply, water heaters, sanitary drainage, vents, traps, interceptors, special waste, storm drainage, materials, joints, testing, and commercial plumbing installation requirements.

The International Fuel Gas Code supports preparation involving gas piping, pipe sizing, appliance installation, combustion air, chimneys, vents, pressure testing, regulators, and fuel-gas safety.

ICC A117.1-2017 supports preparation involving accessible toilet rooms, bathing facilities, fixture heights, clear floor spaces, reach ranges, grab bars, turning spaces, and other accessible plumbing features.

How the Three References Work Together

  • Use the International Plumbing Code for most commercial plumbing-system requirements.
  • Use the International Fuel Gas Code for gas-fired water heaters, gas piping, combustion air, appliance connections, chimneys, and vents.
  • Use ICC A117.1-2017 for accessible plumbing fixtures, toilet rooms, bathing rooms, clearances, heights, and approach spaces.

Some questions may require more than one reference. An accessible toilet room with a gas-fired water heater, for example, can involve plumbing, accessibility, and fuel-gas requirements.

P2 Exam Content Areas

The 2021 P2 examination outline is organized into the following major areas:

  • General Requirements: 8%
  • Fixtures: 15%
  • Water Heaters: 12%
  • Water Supply and Distribution: 18%
  • Sanitary Drainage: 13%
  • Vents: 15%
  • Traps, Interceptors, Separators, Special Piping, and Storage Systems: 9%
  • Storm Drainage: 5%
  • Health Care Plumbing: 5%

Water supply and distribution represents the largest individual content area. Fixtures and vent systems are also major sections of the examination.

What Does a Commercial Plumbing Inspector Do?

A commercial plumbing inspector evaluates plumbing work in commercial, industrial, institutional, multifamily, and other nonresidential buildings.

Common responsibilities may include:

  • Reviewing permits and approved plans
  • Inspecting underground plumbing systems
  • Checking water service and distribution piping
  • Inspecting sanitary drainage and vent systems
  • Reviewing commercial plumbing fixtures
  • Checking accessible toilet and bathing facilities
  • Inspecting water heater installations
  • Reviewing grease interceptors and special waste systems
  • Inspecting storm drainage systems
  • Witnessing required pressure and leakage tests
  • Documenting violations and corrections
  • Coordinating with building, mechanical, electrical, and fire inspectors

The exact inspection authority depends on the jurisdiction, employer, adopted codes, and local administrative requirements.

Confirm Jurisdictional Requirements

Before purchasing the examination or study materials, candidates should verify:

  • Whether the jurisdiction requires P2 certification
  • Which code cycle the jurisdiction accepts
  • Whether state or local exams are also required
  • The current approved references
  • The question count and time limit
  • The scaled passing requirement
  • Rules for tabs, highlighting, and handwritten notes
  • Required commercial plumbing experience
  • Employment or appointment requirements
  • Certification renewal requirements
  • Continuing-education requirements

General Plumbing Requirements

General requirements establish rules for plumbing materials, installation, support, protection, inspections, and testing.

Study subjects may include:

  • Approved materials and equipment
  • Manufacturer installation instructions
  • Protection from corrosion
  • Protection from freezing
  • Structural penetrations
  • Pipe supports and hangers
  • Sleeves and waterproofing
  • Trenching and bedding
  • Required inspections
  • System testing

Piping Protection

Plumbing piping must be protected from physical damage, corrosion, stress, strain, freezing, and incompatible materials.

Inspection considerations may include:

  • Nail plates
  • Corrosion-resistant materials
  • Sleeves through concrete and masonry
  • Protection in traffic areas
  • Freeze protection
  • Burial depth
  • Thermal expansion
  • Settlement and movement
  • Protection beneath footings
  • Separation from harmful substances

Pipe Installation and Support

Piping should be installed with proper alignment, grade, support, expansion allowance, and protection.

Candidates should review:

  • Horizontal support spacing
  • Vertical support requirements
  • Hanger materials
  • Anchoring
  • Expansion and contraction
  • Structural penetrations
  • Firestopping
  • Sleeving
  • Underground installation
  • Accessibility of valves and cleanouts

Commercial Plumbing Fixtures

Commercial plumbing fixtures must be approved, properly installed, accessible where required, and connected to suitable water and drainage systems.

Fixtures may include:

  • Water closets
  • Urinals
  • Lavatories
  • Service sinks
  • Drinking fountains
  • Showers
  • Bathtubs
  • Commercial kitchen sinks
  • Food-preparation sinks
  • Emergency fixtures
  • Floor drains
  • Clinical sinks

Required Plumbing Fixture Counts

Commercial buildings must provide the required number and type of fixtures based on occupancy, occupant load, and applicable code provisions.

Candidates should practice:

  • Identifying the occupancy classification
  • Determining the occupant load
  • Selecting the correct fixture table
  • Separating fixture requirements by sex where applicable
  • Applying permitted substitutions
  • Determining required drinking fountains
  • Determining required service sinks
  • Reviewing employee and public fixture requirements
  • Applying exceptions and table notes

Accessible Plumbing Fixtures

Accessible plumbing fixtures must be installed with required clearances, heights, approach spaces, controls, and support features.

Study subjects may include:

  • Accessible water closets
  • Grab bars
  • Accessible lavatories
  • Knee and toe clearances
  • Accessible urinals
  • Accessible bathing facilities
  • Transfer and roll-in showers
  • Accessible drinking fountains
  • Clear floor spaces
  • Turning spaces
  • Reach ranges
  • Accessible controls and dispensers

Candidates should practice using ICC A117.1 diagrams and dimensional requirements.

Commercial Toilet Rooms

Commercial toilet rooms may require coordination among fixture counts, accessibility, privacy, ventilation, finishes, and building layout.

Inspection considerations may include:

  • Fixture quantity
  • Accessible routes
  • Door maneuvering clearances
  • Water closet compartment dimensions
  • Grab-bar placement
  • Lavatory clearances
  • Mirror and accessory heights
  • Urinal clearances
  • Turning spaces
  • Pipe protection beneath accessible fixtures

Water Heaters

Commercial water heater installations combine plumbing, fuel-gas, mechanical, electrical, structural, and safety requirements.

Study subjects may include:

  • Equipment listing and labeling
  • Installation location
  • Service access
  • Physical protection
  • Drain pans
  • Temperature and pressure relief
  • Relief discharge piping
  • Thermal expansion
  • Seismic restraint where required
  • Gas piping
  • Combustion air
  • Chimneys and vents

Temperature and Pressure Relief

Storage water heaters require approved temperature and pressure relief protection.

Candidates should review:

  • Relief-valve rating
  • Valve location
  • Discharge-pipe materials
  • Discharge-pipe sizing
  • Termination locations
  • Protection from freezing
  • Prohibited valves and restrictions
  • Visible discharge
  • Drainage of discharged water

Relief discharge piping should not be reduced, capped, trapped, or installed in a way that interferes with safe operation.

Fuel-Gas Piping for Water Heaters

Gas-fired water heaters require properly sized fuel piping, accessible shutoff valves, approved appliance connections, combustion air, and compliant venting.

Study areas may include:

  • Connected appliance demand
  • Developed piping length
  • Natural gas and propane tables
  • Low- and elevated-pressure systems
  • Shutoff valves
  • Regulators
  • Sediment traps
  • Appliance connectors
  • Pressure testing
  • Venting categories

Water Supply and Distribution

Commercial water systems must provide an adequate supply of safe water at suitable pressure to all fixtures and equipment.

Study subjects may include:

  • Water service piping
  • Water distribution piping
  • Required water pressure
  • Pressure-reducing valves
  • Water supply fixture units
  • Pipe sizing
  • Shutoff valves
  • Backflow protection
  • Water hammer control
  • Hot-water distribution
  • Nonpotable water systems
  • Disinfection and testing

Water Distribution Pipe Sizing

Water distribution sizing may depend on available pressure, developed length, elevation, fixture demand, pipe material, and expected flow.

A practical sizing process includes:

  • Identify the available water pressure
  • Determine the developed piping length
  • Account for elevation changes
  • Calculate the fixture-unit demand
  • Identify the piping material
  • Select the correct sizing table
  • Determine service and branch sizes
  • Review table notes and limitations

Backflow and Cross-Connection Protection

Backflow protection prevents contaminants and pollutants from entering the potable water system.

Study subjects may include:

  • Air gaps
  • Atmospheric vacuum breakers
  • Pressure vacuum breakers
  • Reduced-pressure assemblies
  • Double-check assemblies
  • Hose connection backflow preventers
  • Cross-connection control
  • Degree of hazard
  • Testing and accessibility
  • Protection of special equipment

Nonpotable Water Systems

Commercial buildings may use reclaimed water, rainwater, gray water, or other approved nonpotable sources.

Inspection considerations may include:

  • System identification
  • Pipe labeling
  • Prohibited cross-connections
  • Backflow protection
  • Storage tanks
  • Treatment equipment
  • Distribution piping
  • Fixture connections
  • Required signs
  • Testing and commissioning

Sanitary Drainage

Sanitary drainage systems carry wastewater from fixtures and equipment to an approved sewer or private disposal system.

Major study areas include:

  • Drainage fixture units
  • Pipe sizing
  • Horizontal drainage slope
  • Drainage fittings
  • Changes in direction
  • Cleanouts
  • Building drains
  • Building sewers
  • Sumps and ejectors
  • Indirect waste
  • Backwater protection
  • Testing

Drainage Fixture Units

Drainage fixture units represent the probable discharge load placed on the sanitary drainage system.

Candidates should practice:

  • Finding fixture-unit values
  • Totaling connected drainage loads
  • Sizing horizontal branches
  • Sizing drainage stacks
  • Sizing building drains
  • Sizing building sewers
  • Applying branch interval limitations
  • Reading table notes and exceptions

Cleanouts

Cleanouts provide access to sanitary drainage piping for inspection, maintenance, and blockage removal.

Study subjects may include:

  • Required cleanout locations
  • Maximum spacing
  • Changes in direction
  • Building drain cleanouts
  • Building sewer cleanouts
  • Cleanout sizing
  • Required working clearances
  • Access panels
  • Protection from concealment

Indirect and Special Waste

Indirect waste systems protect food, equipment, and potable systems from contamination by providing an approved separation from the drainage system.

Applications may include:

  • Food-preparation equipment
  • Commercial dishwashing equipment
  • Ice machines
  • Refrigeration equipment
  • Relief-valve discharge
  • Cooling equipment
  • Sterilizers
  • Clear-water waste
  • Condensate drainage
  • Special industrial waste

Vents

Vent systems protect trap seals, permit air movement, and support proper drainage flow.

Study subjects may include:

  • Individual vents
  • Common vents
  • Wet vents
  • Circuit vents
  • Vent stacks
  • Stack vents
  • Relief vents
  • Combination waste and vent systems
  • Air admittance valves where permitted
  • Vent sizing
  • Vent terminals

Vent Sizing and Installation

Vent size may depend on the connected drainage load, vent length, drain size, and venting method.

A practical review process includes:

  • Identify the venting method
  • Determine the connected drainage fixture units
  • Determine the developed vent length
  • Identify the required drainage pipe size
  • Select the correct vent-sizing table
  • Check minimum size requirements
  • Review horizontal vent grade
  • Confirm the terminal location

Traps

Fixture traps maintain a water seal that prevents sewer gases from entering occupied spaces.

Candidates should review:

  • Required traps
  • Trap seal depth
  • Trap size
  • Trap-arm length
  • Trap protection
  • Prohibited trap arrangements
  • Trap primers
  • Trap accessibility
  • Protection from siphonage and backpressure

Interceptors and Separators

Interceptors and separators remove grease, oil, sediment, solids, or other materials before wastewater enters the drainage system.

Systems may include:

  • Grease interceptors
  • Hydromechanical grease interceptors
  • Gravity grease interceptors
  • Oil separators
  • Sand interceptors
  • Lint interceptors
  • Plaster interceptors
  • Special process separators

Inspection considerations may include sizing, location, venting, accessibility, flow-control devices, maintenance access, and connection arrangements.

Special Piping and Waste Systems

Commercial facilities may contain waste streams that require treatment, neutralization, dilution, cooling, or separate piping.

Study subjects may include:

  • Chemical waste systems
  • Acid-resistant piping
  • Neutralization tanks
  • High-temperature waste
  • Special industrial waste
  • Vacuum drainage systems
  • Compressed-air piping within the exam scope
  • Special storage systems
  • Materials and joining methods

Storm Drainage

Storm drainage systems remove rainwater from roofs, paved areas, and other building surfaces.

Study subjects may include:

  • Roof drains
  • Secondary roof drainage
  • Scuppers
  • Leaders and conductors
  • Horizontal storm piping
  • Rainfall rates
  • Roof drainage areas
  • Subsoil drains
  • Sumps and pumps
  • Combined drainage limitations
  • Discharge locations

Storm Drainage Calculations

Storm drainage sizing may depend on rainfall rate, roof area, vertical wall contribution, pipe slope, drain quantity, and system configuration.

A practical calculation process includes:

  • Determine the contributing roof area
  • Include vertical wall areas where required
  • Identify the applicable rainfall rate
  • Divide the area among drains or scuppers
  • Select the correct sizing table
  • Size vertical conductors
  • Size horizontal storm piping
  • Verify secondary drainage capacity

Health Care Plumbing

Health care facilities may contain specialized piping, equipment, fixtures, and safety systems.

P2 study subjects may include:

  • Medical gas piping
  • Medical vacuum systems
  • Nonflammable medical gases
  • Oxygen piping
  • Service and distribution piping
  • Pipe identification
  • Materials and joining methods
  • Valves and zone controls
  • Testing and verification
  • Special health care fixtures

Candidates should focus on the requirements included within the official P2 exam scope and listed references.

Commercial Plumbing System Testing

Plumbing systems must be inspected and tested before piping is concealed or placed into service.

Testing subjects may include:

  • Water supply pressure tests
  • Drainage and vent tests
  • Water tests
  • Air tests where permitted
  • Fuel-gas pressure tests
  • Storm drainage tests
  • Required test duration
  • Test pressure
  • Inspection of exposed joints
  • Repair and retesting

Commercial Plumbing Plans

P2 candidates should be able to interpret plumbing plans, riser diagrams, fixture schedules, equipment details, accessibility plans, and system layouts.

Plan-reading subjects may include:

  • Fixture locations
  • Water service and distribution
  • Sanitary drainage risers
  • Vent layouts
  • Storm drainage plans
  • Gas piping diagrams
  • Interceptor locations
  • Water heater schedules
  • Accessible toilet-room layouts
  • Medical gas diagrams
  • Plan symbols and abbreviations

Common Commercial Plumbing Deficiencies

  • Insufficient piping support
  • Missing pipe protection
  • Incorrect drainage slope
  • Improper drainage fittings
  • Inaccessible cleanouts
  • Incorrect vent sizing
  • Improper accessible fixture clearances
  • Insufficient plumbing fixture quantities
  • Missing backflow protection
  • Incorrect water heater relief discharge
  • Improper interceptor installation
  • Undersized storm drainage piping
  • Incorrect fuel-gas pipe sizing
  • Incomplete testing before concealment

Open-Book Exam Navigation

With 60 questions and a two-hour-and-30-minute limit, candidates have an average of approximately two minutes and 30 seconds per question.

A practical lookup method includes:

  • Read the complete question
  • Identify whether the subject is plumbing, fuel gas, or accessibility
  • Select the correct reference
  • Identify the primary keyword
  • Use the index or table of contents
  • Locate the complete section, table, or diagram
  • Review definitions, exceptions, and footnotes
  • Confirm that the rule applies to the stated installation
  • Move on when one question is consuming too much time

Organizing the P2 References

A practical tab system may include:

  • IPC general requirements
  • IPC fixtures
  • IPC water heaters
  • IPC water supply
  • IPC backflow protection
  • IPC sanitary drainage
  • IPC indirect waste
  • IPC vents
  • IPC traps and interceptors
  • IPC storm drainage
  • IPC special piping
  • IFGC gas piping
  • IFGC sizing tables
  • IFGC combustion air
  • IFGC chimneys and vents
  • A117.1 toilet rooms
  • A117.1 bathing facilities
  • A117.1 fixture clearances

Candidates should verify current ICC rules before adding tabs, highlighting, handwritten notes, or inserted materials.

Recommended P2 Study Plan

  • Confirm the correct P2 code cycle and references
  • Learn the organization of all three books
  • Review general plumbing requirements and piping protection
  • Study fixture counts and commercial fixture installation
  • Practice accessible toilet-room and bathing-room requirements
  • Review water heater and fuel-gas provisions
  • Practice water supply fixture-unit calculations
  • Practice water distribution pipe sizing
  • Study backflow and nonpotable water systems
  • Review sanitary drainage and cleanouts
  • Practice drainage fixture-unit calculations
  • Study vents, traps, interceptors, and special waste
  • Review storm drainage calculations
  • Study health care plumbing topics
  • Complete timed reference-navigation exercises

Which P2 Package Should You Choose?

  • Choose Online Exam Prep when you already own the correct references and want guided preparation.
  • Choose the Books & Courses Rental Package for temporary book access combined with structured online training.
  • Choose the Highlighted & Tabbed Book Package for professionally organized plumbing, fuel-gas, and accessibility references.
  • Choose the Exam Book Package for independent study and permanent ownership of the listed books.

FAQ

Q. What is the ICC Commercial Plumbing Inspector - P2 exam?

A. It is an ICC national certification examination that evaluates a candidate’s ability to inspect commercial plumbing, fuel-gas, accessibility, storm drainage, and special piping systems for code compliance.

Q. How much does the P2 Online Exam Prep course cost?

A. The sale price is $295.00, reduced from the regular price of $395.00.

Q. How much does the Books & Courses Rental Package cost?

A. The sale price is $940.00, reduced from the regular price of $1,240.00.

Q. How much does the Highlighted & Tabbed Book Package cost?

A. The sale price is $645.00, reduced from the regular price of $845.00.

Q. How much does the P2 Exam Book Package cost?

A. The sale price is $395.00, reduced from the regular price of $495.00.

Q. What references are used for the 2021 P2 exam package?

A. The package identifies the 2021 International Plumbing Code, 2021 International Fuel Gas Code, and ICC A117.1-2017 accessibility standard.

Q. How many questions are on the P2 examination?

A. Official ICC information currently lists 60 questions.

Q. How much time is allowed?

A. Official ICC information currently lists a two-hour-and-30-minute time limit.

Q. Is the P2 exam open book?

A. Yes. Current package information describes the P2 examination as open book. Candidates should verify current reference-use rules before testing.

Q. What score is required to pass?

A. ICC national certification examinations use a scaled passing score of 75. This is not the same as a raw score of 75%.

Q. What subjects should I study?

A. Study general requirements, fixtures, accessibility, water heaters, water supply, sanitary drainage, vents, traps, interceptors, storm drainage, fuel gas, and health care plumbing.

Q. Should I study accessibility requirements?

A. Yes. Candidates should understand accessible fixture heights, clear floor spaces, toilet-room layouts, grab bars, turning spaces, and bathing facilities.

Q. Should I practice water pipe sizing?

A. Yes. Practice available pressure, developed length, elevation, fixture demand, piping material, and sizing-table selection.

Q. Should I practice drainage and vent sizing?

A. Yes. Candidates should practice drainage fixture units, horizontal branches, stacks, building drains, vent loads, developed lengths, and table selection.

Q. Should I study storm drainage?

A. Yes. Review rainfall rates, roof areas, roof drains, leaders, horizontal storm piping, secondary drainage, scuppers, subsoil drains, and sumps.

Q. Does passing P2 automatically authorize me to work as a plumbing inspector?

A. No. A jurisdiction or employer may also require experience, appointment, additional certifications, background qualifications, or local approval.

Q. Can P2 contribute to an ICC Inspector Designation?

A. Yes. Holding both P1 Residential Plumbing Inspector and P2 Commercial Plumbing Inspector can qualify a candidate for the P5 Plumbing Inspector Designation under current ICC requirements.

Q. Is P2 part of the Commercial Combination Inspector designation?

A. Yes. P2 is one of the certifications required for the ICC Commercial Combination Inspector designation, along with the applicable commercial building, electrical, and mechanical inspector certifications.

Q. Where can I purchase the P2 exam prep packages?

A. The available options can be found in the ICC Commercial Plumbing Inspector - P2 exam prep collection.

Conclusion

The ICC Commercial Plumbing Inspector - P2 examination requires candidates to combine commercial plumbing knowledge with efficient use of plumbing, fuel-gas, and accessibility references.

Important preparation subjects include fixtures, accessibility, water heaters, water supply, backflow protection, sanitary drainage, vents, traps, interceptors, storm drainage, fuel-gas systems, health care plumbing, testing, calculations, plans, and inspection documentation.

1 Exam Prep offers online exam preparation, rental books with course access, highlighted and tabbed references, and an exam book package for different preparation needs and budgets.

Shop ICC Commercial Plumbing Inspector - P2 Exam Prep

Key Takeaways

  • P2 is the ICC Commercial Plumbing Inspector national certification examination.
  • The Online Exam Prep sale price is $295.00.
  • The Books & Courses Rental Package sale price is $940.00.
  • The Highlighted & Tabbed Book Package sale price is $645.00.
  • The Exam Book Package sale price is $395.00.
  • Official ICC information lists 60 questions and a two-hour-and-30-minute limit.
  • The current package describes the examination as open book.
  • The listed references are the 2021 IPC, 2021 IFGC, and ICC A117.1-2017.
  • ICC national certification exams use a scaled passing score of 75.
  • Major subjects include fixtures, water heaters, water supply, drainage, vents, accessibility, and storm drainage.
  • P2 can contribute to ICC plumbing and commercial combination inspector designations.
  • Passing P2 does not automatically provide inspection authority in every jurisdiction.
  • Candidates should verify the current code cycle and local qualification requirements before registering.