ICC Fire Inspector II - 67 Exam Prep Guide

The ICC Fire Inspector II - 67 examination is designed for fire inspectors, fire prevention personnel, code officials, building safety professionals, fire marshals, investigators, and other professionals responsible for advanced fire and life-safety inspections.

Fire Inspector II work can involve evaluating complex occupancies, identifying fire hazards, reviewing hazardous materials and regulated operations, documenting violations, coordinating corrective action, preparing inspection reports, supporting enforcement proceedings, and communicating with property owners, contractors, emergency personnel, and other code officials.

The ICC Fire Inspector II - 67 collection currently includes a complete exam book package for candidates preparing to study the applicable building-code, fire-code, and fire-inspection materials.

Available Fire Inspector II Exam Book Package

  • ICC Fire Inspector II - 67 Exam Book Package: $595.00 sale price, reduced from $695.00

The package is intended for candidates who want the primary code and inspection materials organized into one study set.

Because Fire Inspector II questions may involve building construction, fire-code operations, hazardous materials, inspection administration, and enforcement procedures, candidates should learn which reference applies to each type of question.

Fire Inspector II Study References

For the 2021 code cycle, ICC study materials identify the following publications:

  • International Building Code, 2021 Edition
  • International Fire Code, 2021 Edition
  • Fire Inspection and Code Enforcement

The International Building Code supports preparation involving occupancy classification, construction types, fire-resistance-rated construction, means of egress, fire protection systems, interior finishes, high-rise buildings, and other building-related fire safety requirements.

The International Fire Code supports preparation involving fire prevention, operational permits, fire department access, fire protection systems, emergency planning, hazardous materials, combustible storage, special operations, and ongoing maintenance requirements.

Fire Inspection and Code Enforcement supports preparation involving inspection procedures, report writing, evidence, interviewing, public education, enforcement, legal considerations, hazardous conditions, and the professional responsibilities of a fire inspector.

Candidates should confirm the exact editions included in the current package and listed for their selected ICC code cycle before registering for the examination.

What Is the ICC Fire Inspector II - 67 Examination?

The Fire Inspector II - 67 exam is an ICC national certification examination focused on advanced fire inspection and code-enforcement knowledge.

Current official ICC information lists:

  • 50 examination questions
  • Two-hour time limit
  • National certification examination
  • Scaled passing score of 75

A scaled score of 75 is not the same as answering exactly 75% of the questions correctly. ICC converts raw examination results to a standardized scale so that the passing standard remains consistent across different versions of the exam.

Candidates should review the current ICC Exam Catalog for permitted references, testing methods, book-modification rules, and code-cycle options.

What Does a Fire Inspector II Do?

A Fire Inspector II generally performs advanced inspections and code-enforcement duties involving more complex buildings, operations, materials, and fire safety conditions.

Common responsibilities may include:

  • Planning and conducting fire inspections
  • Reviewing occupancy and operational permits
  • Evaluating complex or high-hazard occupancies
  • Inspecting fire protection systems
  • Reviewing hazardous materials storage and use
  • Evaluating emergency planning and preparedness
  • Identifying unsafe fire and life-safety conditions
  • Preparing detailed inspection reports
  • Issuing or supporting correction notices
  • Coordinating reinspection and enforcement activity
  • Collecting and preserving inspection evidence
  • Providing code information to owners and occupants
  • Supporting public fire-safety education
  • Testifying or participating in administrative proceedings

The exact duties of a Fire Inspector II depend on the jurisdiction, employer, adopted codes, organizational structure, and assigned authority.

Fire Inspector I Versus Fire Inspector II

Fire Inspector II responsibilities are generally more advanced than foundational fire inspection duties.

  • Fire Inspector I: Commonly focuses on routine inspections, basic fire hazards, fire protection equipment, means of egress, general occupancy safety, and standard documentation.
  • Fire Inspector II: Commonly addresses more complex occupancies, regulated materials, special processes, advanced enforcement, inspection planning, detailed reports, and coordination with other authorities.

A jurisdiction or employer may require prior Fire Inspector I certification, qualifying experience, additional education, or other credentials before assigning Fire Inspector II duties.

Major Fire Inspector II Study Areas

ICC study materials emphasize the following broad areas:

  • General inspection administration
  • General provisions for fire safety
  • Occupancies
  • Regulated materials and processes

These areas require candidates to combine code navigation with professional inspection judgment, documentation, communication, and enforcement knowledge.

General Inspection Administration

Inspection administration covers how fire inspections are planned, performed, documented, communicated, and enforced.

Study subjects may include:

  • Authority of the fire code official
  • Inspection preparation
  • Inspection scheduling
  • Review of permits and records
  • Inspection procedures
  • Right of entry
  • Professional conduct
  • Documentation and evidence
  • Correction notices
  • Reinspection procedures
  • Appeals and administrative processes
  • Coordination with other agencies

Preparing for a Fire Inspection

Preparation helps the inspector understand the property, occupancy, known hazards, and purpose of the inspection before arriving on site.

Preparation may include:

  • Reviewing previous inspection reports
  • Checking permits and certificates
  • Reviewing complaints or incident history
  • Identifying occupancy classification
  • Reviewing hazardous materials information
  • Checking approved plans
  • Identifying required fire protection systems
  • Preparing inspection forms and equipment
  • Coordinating with facility representatives
  • Determining whether additional specialists are needed

Conducting the Inspection

A systematic inspection process helps ensure that important areas are not overlooked.

A practical inspection sequence may include:

  • Meet the responsible facility representative
  • Explain the purpose and scope of the inspection
  • Confirm the building use and occupancy
  • Review required permits and records
  • Inspect exterior access and fire department features
  • Inspect means of egress
  • Review fire protection systems
  • Inspect storage and operational areas
  • Evaluate hazardous materials and special processes
  • Document observed violations
  • Conduct an exit interview
  • Explain required corrections and follow-up procedures

Inspection Reports

Inspection reports should accurately describe the property, conditions observed, applicable requirements, required corrections, and compliance deadlines.

Reports may include:

  • Property and contact information
  • Date and type of inspection
  • Areas inspected
  • Permit and occupancy information
  • Observed fire or life-safety hazards
  • Applicable code sections
  • Required corrective action
  • Correction deadlines
  • Photographs or diagrams
  • Reinspection requirements
  • Inspector identification
  • Acknowledgment by the responsible party

Reports should use objective language and clearly separate observed facts from assumptions or recommendations.

Evidence and Documentation

Inspection findings may become part of an enforcement action, appeal, hearing, or legal proceeding. Documentation should be accurate, complete, and professionally maintained.

Evidence may include:

  • Written notes
  • Photographs
  • Video recordings where permitted
  • Measurements
  • Equipment test records
  • Maintenance documents
  • Permit records
  • Witness statements
  • Samples collected under approved procedures
  • Plans and diagrams

Candidates should understand agency procedures for preserving records and maintaining the integrity of evidence.

Correction Notices and Enforcement

When violations are identified, the inspector should follow the enforcement procedures established by the adopted code and jurisdiction.

Possible actions may include:

  • Verbal notification
  • Written correction notice
  • Notice of violation
  • Reinspection
  • Administrative citation
  • Permit suspension or revocation
  • Stop-work order
  • Evacuation or closure
  • Referral for legal action
  • Alternative compliance agreement where permitted

The selected action should be consistent with the inspector’s authority, agency policy, severity of the hazard, and applicable legal requirements.

General Fire Safety Provisions

General fire safety provisions apply across many buildings, occupancies, and operations.

Important study subjects may include:

  • Fire department access
  • Premises identification
  • Fire lanes
  • Key boxes and access systems
  • Combustible waste
  • Open flames
  • Smoking controls
  • Hot work
  • Electrical fire hazards
  • Vacant buildings
  • Emergency planning
  • Fire safety during construction

Fire Department Access

Fire department access provisions help emergency responders reach buildings, fire protection equipment, water supplies, and incident locations.

Inspection subjects may include:

  • Fire apparatus access roads
  • Required access width and height
  • Turning radius
  • Road surface and load capacity
  • Gates and barriers
  • Fire lane markings
  • Obstructions
  • Access to hydrants
  • Address identification
  • Access to fire department connections

Means of Egress

Means-of-egress systems provide a continuous path from occupied spaces to a safe exterior location.

Candidates should review:

  • Required number of exits
  • Exit access
  • Exit separation
  • Travel distance
  • Common path of travel
  • Corridor width
  • Door operation
  • Panic and fire exit hardware
  • Stairways and ramps
  • Emergency lighting
  • Exit signs
  • Obstructions and storage

Fire inspectors should recognize temporary and permanent conditions that reduce the capacity, visibility, accessibility, or reliability of an exit system.

Occupant Load

Occupant load affects the number and capacity of exits, door hardware, seating arrangements, and other life-safety provisions.

Candidates should practice:

  • Identifying the use of a space
  • Selecting the correct occupant-load factor
  • Calculating occupant load
  • Evaluating fixed seating
  • Reviewing posted occupant-load signs
  • Determining required exit capacity
  • Identifying overcrowding conditions
  • Reviewing multiple-use spaces

Fire Protection Systems

Fire inspectors should understand the purpose, basic components, inspection status, and maintenance requirements of installed fire protection systems.

Systems may include:

  • Automatic sprinkler systems
  • Standpipe systems
  • Fire alarm systems
  • Smoke detection systems
  • Commercial kitchen suppression systems
  • Special hazard suppression systems
  • Portable fire extinguishers
  • Smoke-control systems
  • Fire pumps
  • Private fire hydrants

The Fire Inspector II exam may focus on recognizing required systems, reviewing records, identifying impairments, and applying fire-code requirements rather than performing specialized technical system design.

Fire Protection System Records

Inspection, testing, and maintenance records help establish whether a system has been serviced and remains operational.

Inspectors may review:

  • Sprinkler inspection reports
  • Fire alarm testing records
  • Fire pump test reports
  • Standpipe test records
  • Kitchen suppression inspection tags
  • Fire extinguisher service records
  • Smoke-control testing documents
  • Impairment records
  • Repair documentation
  • Acceptance-test reports

Impaired Fire Protection Systems

A fire protection system is impaired when it cannot perform its intended function.

Impairment procedures may involve:

  • Identifying the affected system
  • Determining the extent of the impairment
  • Notifying responsible parties
  • Notifying the fire department where required
  • Notifying monitoring services
  • Implementing a fire watch
  • Controlling hazardous operations
  • Completing repairs
  • Testing the restored system
  • Documenting restoration

Emergency Planning and Preparedness

Some buildings and operations require emergency plans, evacuation procedures, employee training, drills, and communication systems.

Candidates should study:

  • Fire safety and evacuation plans
  • Emergency action plans
  • Employee training
  • Fire drills
  • Staff responsibilities
  • Emergency communication
  • Assistance for occupants requiring support
  • Accounting for occupants
  • Emergency contact information
  • Plan maintenance and review

Occupancy Classification

Occupancy classification describes how a building or space is used and affects fire protection, means of egress, operational permits, hazardous materials, and life-safety requirements.

Candidates should review:

  • Assembly occupancies
  • Business occupancies
  • Educational occupancies
  • Factory and industrial occupancies
  • High-hazard occupancies
  • Institutional occupancies
  • Mercantile occupancies
  • Residential occupancies
  • Storage occupancies
  • Utility and miscellaneous occupancies
  • Mixed occupancies

Correct occupancy classification is often the first step in applying the correct fire and life-safety requirements.

Assembly Occupancies

Assembly occupancies may include restaurants, theaters, places of worship, meeting halls, clubs, sports facilities, and other gathering spaces.

Inspection subjects may include:

  • Occupant load
  • Exit quantity and capacity
  • Seating arrangements
  • Aisles
  • Tables and chairs
  • Panic hardware
  • Decorative materials
  • Open flames
  • Cooking operations
  • Emergency lighting and exit signs
  • Crowd managers where required

Educational and Institutional Occupancies

Schools, day-care facilities, hospitals, nursing facilities, detention facilities, and other institutional occupancies present special life-safety concerns.

Candidates should review:

  • Evacuation capabilities
  • Staff responsibilities
  • Emergency plans
  • Fire drills
  • Door locking arrangements
  • Corridor protection
  • Smoke compartments
  • Defend-in-place procedures
  • Patient or resident movement
  • Fire protection systems

Residential Occupancies

Residential fire inspections may involve hotels, apartment buildings, dormitories, assisted living facilities, and other sleeping occupancies.

Study subjects may include:

  • Smoke alarms and detection
  • Carbon monoxide alarms
  • Fire alarm systems
  • Automatic sprinkler systems
  • Exit access
  • Door and corridor protection
  • Emergency lighting
  • Housekeeping
  • Portable heating equipment
  • Laundry and cooking hazards

Industrial and Storage Occupancies

Industrial and storage facilities may present hazards involving combustible materials, machinery, ignition sources, high-piled storage, and hazardous processes.

Candidates should review:

  • Commodity classifications
  • Storage height
  • Aisle width
  • Rack storage
  • High-piled combustible storage
  • Flue spaces
  • Storage near sprinklers
  • Battery charging
  • Hot work
  • Dust-producing operations
  • Fire department access

High-Piled Combustible Storage

High-piled storage can affect sprinkler design, access, smoke and heat removal, aisle arrangements, and fire department operations.

Inspection considerations may include:

  • Commodity classification
  • Storage height
  • Storage area
  • Rack configuration
  • Aisles
  • Flue spaces
  • Sprinkler clearance
  • Required permits
  • Fire department access doors
  • Approved storage plans

Hazardous Materials

Hazardous materials requirements depend on the material’s physical and health hazards, quantity, storage method, use, location, and occupancy.

Hazard categories may include:

  • Flammable liquids
  • Combustible liquids
  • Flammable gases
  • Oxidizers
  • Organic peroxides
  • Corrosives
  • Toxic and highly toxic materials
  • Pyrophoric materials
  • Water-reactive materials
  • Unstable reactive materials
  • Cryogenic fluids
  • Compressed gases

Hazardous Materials Inventory

Fire inspectors may review material inventories to determine whether quantities exceed permit, control area, or maximum allowable quantity limits.

Inventory review may involve:

  • Material identity
  • Hazard classification
  • Physical state
  • Container size
  • Total quantity
  • Storage or use condition
  • Indoor or outdoor location
  • Control areas
  • Floor level
  • Sprinkler protection
  • Safety data sheets

Maximum Allowable Quantities

Maximum allowable quantity provisions limit the amount of hazardous material that may be stored or used within a control area before additional requirements or a high-hazard occupancy classification applies.

Candidates should practice:

  • Identifying the material hazard class
  • Determining whether the material is stored or used
  • Distinguishing closed and open systems
  • Applying indoor or outdoor provisions
  • Applying sprinkler increases where permitted
  • Applying cabinet or room increases where permitted
  • Reviewing control-area limitations
  • Evaluating multiple materials

Flammable and Combustible Liquids

Inspection of flammable and combustible liquids may involve containers, tanks, dispensing, transfer, ventilation, spill control, and ignition-source control.

Study subjects may include:

  • Liquid classification
  • Container and tank limits
  • Storage cabinets
  • Inside storage rooms
  • Liquid storage warehouses
  • Dispensing and transfer
  • Secondary containment
  • Spill control
  • Ventilation
  • Electrical equipment
  • Bonding and grounding

Compressed Gases and Cryogenic Fluids

Compressed gases and cryogenic fluids can create pressure, fire, toxicity, oxygen displacement, and physical hazards.

Inspection subjects may include:

  • Cylinder securing
  • Valve protection
  • Separation of incompatible materials
  • Ventilation
  • Gas cabinets
  • Exhausted enclosures
  • Leak detection
  • Emergency controls
  • Outdoor storage
  • Vehicle impact protection
  • Warning signs

Combustible Dust

Combustible dust can create flash-fire and explosion hazards when fine particles accumulate or become suspended in air.

Inspection considerations may include:

  • Dust-producing operations
  • Dust collection systems
  • Housekeeping
  • Accumulated dust
  • Ignition sources
  • Electrical equipment
  • Explosion control
  • Deflagration venting
  • Equipment bonding and grounding
  • Hot-work controls

Hot Work

Hot work includes welding, cutting, brazing, soldering, grinding, and other activities capable of producing flames, sparks, or heat.

Candidates should review:

  • Hot-work permits
  • Designated hot-work areas
  • Fire watches
  • Removal of combustible materials
  • Protection of openings
  • Fire extinguisher availability
  • Gas cylinder handling
  • Post-work monitoring
  • Contractor responsibilities
  • Prohibited conditions

Special Operations and Processes

Fire Inspector II candidates may encounter regulated operations that require specialized permits, controls, and inspection procedures.

Possible subjects include:

  • Spray finishing
  • Dip tanks
  • Industrial ovens
  • Combustible dust operations
  • Semiconductor fabrication
  • Motor fuel dispensing
  • Repair garages
  • Aircraft-related facilities
  • High-piled storage
  • Open burning
  • Temporary membrane structures
  • Explosives and fireworks

Motor Fuel Dispensing Facilities

Fuel-dispensing facilities present hazards involving flammable liquids, vehicle traffic, electrical equipment, spills, and emergency shutdown systems.

Inspection areas may include:

  • Dispensers and hoses
  • Emergency shutoff controls
  • Vehicle impact protection
  • Spill response equipment
  • Warning signs
  • Ignition-source control
  • Portable containers
  • Fuel delivery operations
  • Maintenance activities
  • Alternative fuel systems

Fire Safety During Construction and Demolition

Buildings under construction or demolition can have incomplete fire protection, temporary access problems, exposed combustible materials, and active hot-work hazards.

Candidates should review:

  • Fire department access
  • Temporary standpipes
  • Water supplies
  • Portable fire extinguishers
  • Hot-work controls
  • Combustible debris
  • Temporary heating
  • Smoking controls
  • Security and site access
  • Fire protection system impairments
  • Emergency contact information

Vacant and Abandoned Buildings

Vacant buildings can present increased risks of unauthorized entry, arson, structural deterioration, and delayed fire discovery.

Inspection considerations may include:

  • Securing openings
  • Premises identification
  • Fire department access
  • Combustible waste
  • Utility control
  • Structural hazards
  • Fire protection system status
  • Unauthorized occupancy
  • Vegetation and exterior hazards
  • Required monitoring or patrols

Public Fire-Safety Education

Fire inspectors may help property owners, employees, and community members understand fire hazards and compliance responsibilities.

Education activities may include:

  • Explaining correction notices
  • Providing evacuation guidance
  • Discussing extinguisher use
  • Supporting fire drill planning
  • Providing seasonal fire-safety information
  • Discussing hazardous material storage
  • Explaining permit requirements
  • Helping businesses develop safer operating practices

Communication and Interviewing

Fire inspectors regularly communicate with owners, occupants, employees, contractors, attorneys, emergency personnel, and other officials.

Effective communication includes:

  • Explaining the purpose of an inspection
  • Asking clear and relevant questions
  • Listening carefully
  • Maintaining professional conduct
  • Explaining violations objectively
  • Avoiding unsupported conclusions
  • Documenting important statements
  • Managing conflict
  • Using interpreters or accessible communication when needed

Legal and Ethical Considerations

Fire inspectors should understand the limits of their authority and the importance of fair, consistent, and ethical enforcement.

Study subjects may include:

  • Due process
  • Right of entry
  • Administrative warrants
  • Confidentiality
  • Public records
  • Evidence handling
  • Equal enforcement
  • Conflicts of interest
  • Professional ethics
  • Testimony and hearings
  • Agency policies

Code Navigation Strategy

The examination requires candidates to move efficiently among building-code, fire-code, and inspection-practice materials.

A practical lookup process includes:

  • Read the complete question
  • Identify whether it concerns building construction, fire operations, hazardous materials, or inspection procedure
  • Select the most likely reference
  • Use the index, table of contents, or chapter headings
  • Locate the complete section, table, or procedure
  • Review definitions, exceptions, and footnotes
  • Confirm that the requirement applies to the described occupancy or operation
  • Move on when a question is taking too much time

Choosing the Correct Study Reference

  • Building construction or life-safety design: Begin with the International Building Code.
  • Operational fire safety or hazardous materials: Begin with the International Fire Code.
  • Inspection procedure, documentation, interviewing, or enforcement: Begin with Fire Inspection and Code Enforcement.

Some questions may require candidates to connect information from more than one reference.

Organizing the Fire Inspector II References

A practical study index may include:

  • Administration and authority
  • Occupancy classification
  • Construction types
  • Fire-resistance-rated construction
  • Means of egress
  • Fire protection systems
  • Fire department access
  • Emergency planning
  • Assembly occupancies
  • Institutional occupancies
  • High-piled storage
  • Hazardous materials
  • Flammable liquids
  • Compressed gases
  • Combustible dust
  • Hot work
  • Inspection reports
  • Evidence and enforcement

Candidates should verify ICC’s current rules before adding tabs, highlighting, handwritten notes, or other modifications to books used during testing.

Recommended Fire Inspector II Study Plan

  • Confirm the current exam code cycle and reference list
  • Learn the organization of all listed publications
  • Review inspection administration and enforcement procedures
  • Study occupancy classification and building construction
  • Review means of egress and occupant-load calculations
  • Study fire protection system requirements and impairments
  • Review emergency planning and fire drills
  • Study assembly, institutional, residential, and industrial occupancies
  • Review high-piled combustible storage
  • Study hazardous material classifications and quantities
  • Review flammable liquids and compressed gases
  • Study combustible dust, hot work, and special operations
  • Practice inspection report and violation scenarios
  • Complete timed reference-navigation exercises
  • Review every missed practice question

Common Fire Inspector II Preparation Mistakes

  • Studying only the International Fire Code
  • Ignoring building-code life-safety requirements
  • Failing to study inspection procedures and report writing
  • Memorizing rules without practicing code navigation
  • Confusing occupancy classifications
  • Skipping hazardous materials tables and definitions
  • Ignoring exceptions and table notes
  • Failing to practice occupant-load calculations
  • Studying from the wrong code cycle
  • Waiting until exam day to organize the references

FAQ

Q. What is the ICC Fire Inspector II - 67 exam?

A. It is an ICC national certification examination focused on advanced fire inspection, fire-code enforcement, occupancy safety, hazardous materials, regulated operations, documentation, and inspection administration.

Q. How much does the Fire Inspector II Exam Book Package cost?

A. The sale price is $595.00, reduced from the regular price of $695.00.

Q. How many questions are on the Fire Inspector II exam?

A. Official ICC information currently lists 50 questions.

Q. How much time is allowed for the exam?

A. Official ICC information currently lists a two-hour time limit.

Q. What score is required to pass?

A. ICC national certification examinations use a scaled passing score of 75. The scaled score is not the same as a raw percentage.

Q. What references should I study?

A. For the 2021 code cycle, ICC study materials identify the 2021 International Building Code, 2021 International Fire Code, and Fire Inspection and Code Enforcement.

Q. Is the Fire Inspector II exam open book?

A. Candidates should confirm the current reference-use and testing rules in the ICC Exam Catalog for the code cycle and testing method they select.

Q. What subjects should I study?

A. Study inspection administration, fire safety, occupancies, means of egress, fire protection systems, hazardous materials, special processes, report writing, documentation, and enforcement.

Q. What is the difference between Fire Inspector I and Fire Inspector II?

A. Fire Inspector II generally addresses more complex occupancies, hazardous materials, regulated processes, advanced documentation, enforcement, and inspection-management responsibilities.

Q. Should I study the International Building Code?

A. Yes. Building construction, occupancy, fire resistance, means of egress, and fire protection requirements can affect fire inspection decisions.

Q. Should I study hazardous materials?

A. Yes. Candidates should review hazard classifications, inventories, maximum allowable quantities, storage, use, control areas, and emergency procedures.

Q. Should I practice occupant-load calculations?

A. Yes. Occupant load affects exit quantity, exit capacity, seating arrangements, posted limits, and other life-safety provisions.

Q. Should I study inspection reports and enforcement?

A. Yes. Fire Inspector II preparation should include documentation, correction notices, reinspections, evidence, appeals, and enforcement procedures.

Q. Does passing exam 67 automatically authorize me to work as a Fire Inspector II?

A. No. A jurisdiction or employer may also require experience, Fire Inspector I certification, appointment, background qualifications, education, or additional credentials.

Q. Where can I purchase the Fire Inspector II Exam Book Package?

A. The package is available in the ICC Fire Inspector II - 67 collection.

Conclusion

The ICC Fire Inspector II - 67 examination requires candidates to combine advanced fire inspection knowledge with efficient use of building-code, fire-code, and inspection-enforcement materials.

Important preparation subjects include administration, occupancies, means of egress, fire protection systems, emergency planning, hazardous materials, high-piled storage, flammable liquids, compressed gases, combustible dust, hot work, documentation, evidence, and enforcement.

The ICC Fire Inspector II - 67 Exam Book Package provides a focused reference set for candidates preparing to improve their code-navigation skills and study the responsibilities associated with advanced fire inspection work.

Shop the ICC Fire Inspector II - 67 Exam Book Package

Key Takeaways

  • Exam 67 is the ICC Fire Inspector II national certification examination.
  • The Exam Book Package sale price is $595.00.
  • The regular package price is $695.00.
  • Official ICC information lists 50 questions and a two-hour time limit.
  • National certification examinations use a scaled passing score of 75.
  • The 2021 study materials identify the 2021 IBC, 2021 IFC, and Fire Inspection and Code Enforcement.
  • Major subjects include inspection administration, fire safety, occupancies, and regulated materials and processes.
  • Hazardous materials and advanced enforcement are important Fire Inspector II study areas.
  • Passing the exam does not automatically provide inspection authority in every jurisdiction.
  • Candidates should verify the current code cycle, references, and employer requirements before registering.