Connecticut Limited Gas and Oil Burner Journeyperson (B-2) Books Allowed into Exam Package

Connecticut Limited Gas and Oil Burner Journeyperson (B-2) Books Allowed into Exam Package

Regular price $1,295.00
Sale price $1,295.00 Regular price $1,395.00
Sale Sold out
Shipping calculated at checkout.

CALL TO ASK ABOUT FINANCIAL ASSISTANCE

  • image-right
Customer Reviews
View full details

Connecticut Limited Gas and Oil Burner Journeyperson (B-2) Books Allowed into Exam Package

Prepare for the Connecticut Limited Gas and Oil Burner Journeyperson (B-2) examination with a focused package containing the six technical references identified for use during the open-book trade exam. This package is designed for apprentices, burner technicians, heating professionals, fuel-gas installers, oil-heating technicians, service professionals, and qualified applicants pursuing the Connecticut B-2 journeyperson license.

The Connecticut B-2 examination evaluates knowledge related to the installation, repair, replacement, alteration, and maintenance of gas and oil burners used in domestic and light commercial applications. Candidates should understand fuel-gas systems, natural gas, liquefied petroleum gas, oil-burning equipment, controls, piping, valves, combustion air, chimneys, flues, vents, equipment installation, system testing, maintenance, and safe work practices.

This package includes the International Mechanical Code, 2021, International Residential Code for One- and Two-Family Dwellings, 2021, International Fuel Gas Code, 2021, NFPA 31: Standard for the Installation of Oil-Burning Equipment, 2011, NFPA 54: National Fuel Gas Code Handbook, 2012, and NFPA 58: Liquefied Petroleum Gas Code, 2014.

Each reference supports a different portion of the examination. The mechanical and residential codes address equipment installation, appliance clearances, service access, combustion air, fuel systems, chimneys, vents, and residential requirements. The International Fuel Gas Code and NFPA 54 support natural-gas piping, appliance connections, pressure regulation, testing, purging, combustion air, and venting.

NFPA 31 focuses on oil-burning appliances, burners, fuel tanks, oil piping, controls, combustion air, venting, and related installation requirements. NFPA 58 covers liquefied petroleum gas containers, regulators, piping, separation distances, equipment, storage, handling, testing, and system safety.

The Connecticut B-2 examination is open book and timed. Having the approved references available does not replace technical knowledge or exam preparation. Candidates should understand which book covers each subject, know how the references are organized, and practice locating code provisions, definitions, tables, exceptions, and equipment requirements efficiently.

This Books Allowed into Exam Package contains only the six listed exam-room references. Additional study books, online course access, highlighting and tabbing, Application Service, examination registration, government fees, book rental, and professional licensing approval are not identified as included.

Exam Details

The Connecticut B-2 Limited Gas and Oil Burner Journeyperson examination contains 40 questions. Candidates receive one and one-half hours to complete the examination and must earn a minimum score of 70 percent.

The examination content areas include:

  • Chimneys, Flues, and Vents
  • Controls
  • Equipment
  • Fuel Gas Systems
  • General Knowledge
  • Oil Burners
  • Piping and Valves
  • Testing and Maintenance
  • Liquefied Petroleum Gas
  • Natural Gas

Fuel-gas systems represent an important part of the examination. Candidates should review approved piping materials, pipe sizing, appliance loads, developed length, system pressure, regulators, shutoff valves, sediment traps, appliance connections, leak testing, purging, combustion air, venting, and installation safety.

Natural-gas questions may involve piping capacity, operating pressure, regulator operation, appliance input, equipment connections, testing, combustion air, and venting. Candidates should understand how system pressure, pipe material, total connected load, and piping length affect gas-pipe sizing.

Liquefied petroleum gas questions may address containers, regulators, piping, equipment, storage, separation distances, installation, testing, handling, and safety. Candidates should recognize that LP-gas requirements may differ from natural-gas requirements and should use the correct reference for each fuel type.

Oil-burner questions may involve storage tanks, supply piping, filters, pumps, nozzles, burner motors, ignition components, combustion, draft, venting, controls, testing, adjustment, and maintenance. Candidates should understand how nozzle selection, fuel pressure, combustion air, ignition, and draft affect burner performance.

Control questions may involve thermostats, transformers, relays, primary controls, limit controls, flame-safeguard devices, gas valves, ignition systems, motors, and emergency switches. Candidates should understand the purpose of each control and the operating sequence of a burner system.

Equipment questions may address boilers, furnaces, burners, heat exchangers, combustion chambers, tanks, regulators, valves, venting systems, and related accessories. Preparation should include equipment location, clearances, accessibility, combustion air, and safe installation practices.

Piping and valve questions may involve approved materials, fittings, supports, joining methods, shutoff devices, regulators, oil lines, gas piping, appliance connections, and system testing. Improper sizing or installation can result in inadequate fuel delivery, leakage, poor combustion, or unsafe equipment operation.

Testing and maintenance questions may include leak testing, smoke testing, draft measurement, combustion analysis, equipment inspection, cleaning, troubleshooting, startup, shutdown, and verification of safe operation.

Open Book Test

The Connecticut Limited Gas and Oil Burner Journeyperson (B-2) trade examination is an open-book test. Candidates are responsible for bringing their own approved references to the examination center.

The examination provides 90 minutes for 40 questions. That leaves slightly more than two minutes per question. Candidates who are unfamiliar with their references may lose valuable time deciding where to search or moving between several codes for one problem.

Reference books may be highlighted, underlined, annotated, or indexed before the examination. Permanent tabs may be used to mark important chapters, tables, definitions, and frequently referenced provisions. Temporary or repositionable tabs are not permitted.

Candidates may not write in the books during the examination. Loose papers and unauthorized attached materials are not allowed. Questions and answers written into the references must be removed before entering the testing room.

A silent, nonprinting, non-programmable calculator may be used during the examination. Candidates should practice using an approved calculator when completing fuel-gas sizing exercises and other trade calculations.

For gas-pipe sizing questions, candidates must use the longest-length method. This method generally requires the candidate to identify the longest developed piping length in the system and use that length when selecting pipe sizes for the connected appliance loads.

Practice identifying the correct fuel, operating pressure, pipe material, developed length, and appliance demand before selecting a sizing table. Always read table headings, notes, limitations, and related provisions before choosing an answer.

Use the International Mechanical Code, 2021 for mechanical equipment, appliance installation, combustion air, fuel systems, chimneys, vents, clearances, service access, and general mechanical safety requirements.

Use the International Residential Code for One- and Two-Family Dwellings, 2021 for mechanical and fuel-gas requirements that apply to qualifying residential construction. Important topics include appliance locations, equipment clearances, combustion air, fuel piping, venting, and residential installation requirements.

Use the International Fuel Gas Code, 2021 for gas-piping systems, pressure regulators, appliance connections, testing, purging, combustion air, venting, gas-utilization equipment, and fuel-gas safety.

Use NFPA 31 for questions involving oil-burning appliances, fuel tanks, oil piping, burners, controls, combustion air, venting, installation, and operation. Candidates should become familiar with the standard’s definitions, equipment requirements, tables, and safety provisions.

Use the NFPA 54 National Fuel Gas Code Handbook for natural-gas piping, appliance installation, pressure regulation, combustion air, testing, purging, venting, and longest-length sizing guidance.

Use NFPA 58 for LP-gas containers, regulators, piping, equipment, storage, handling, separation distances, testing, installation, and safety.

Develop a consistent search method before test day. Identify the main subject in the question, choose the most relevant book, use the index or table of contents, and read the complete applicable section. Review definitions, exceptions, table notes, figures, and cross-references before selecting an answer.

Licensing Steps

The Connecticut Department of Consumer Protection regulates occupational trade licenses and determines examination eligibility. PSI administers the B-2 examination after Connecticut approves the applicant.

  1. Confirm the B-2 classification. Review the Limited Gas and Oil Burner Journeyperson scope and determine whether it matches the work you intend to perform.
  2. Complete the required training pathway. Applicants may qualify by completing a registered apprenticeship program associated with the B-2 license.
  3. Use an equivalent pathway when applicable. Applicants may submit equivalent experience and training for review by the Connecticut Department of Consumer Protection.
  4. Complete the state application. Submit the required personal, apprenticeship, training, education, employment, and licensing information.
  5. Provide supporting records. Submit apprenticeship completion documents, classroom records, on-the-job training records, employer verification, or equivalent-experience documentation requested by Connecticut.
  6. Obtain third-party verification. Employers, supervisors, apprenticeship sponsors, training providers, or licensing agencies may need to confirm information.
  7. Receive examination approval. Connecticut must determine that the applicant meets the eligibility requirements before testing.
  8. Register with PSI. After approval, create or access the testing account, pay the applicable examination charge, and schedule the B-2 examination.
  9. Prepare the exam-room references. Confirm that the books, tabs, annotations, and calculator comply with current testing rules.
  10. Take the B-2 examination. Bring acceptable identification, approved references, and a permitted calculator while following testing-center procedures.
  11. Complete the licensing process. Submit the passing examination result, licensing charges, and any remaining documents required by Connecticut.

The B-2 is a journeyperson-level credential. The separate Business and Law examination associated with Connecticut contractor classifications is not identified as part of the B-2 journeyperson trade examination.

This Books Allowed into Exam Package does not include Application Service, state application preparation, PSI registration, examination charges, licensing fees, or submission of licensing documents.

State Requirements

The Connecticut B-2 Limited Gas and Oil Burner Journeyperson license authorizes qualifying burner and fuel-system work within the limitations established for the credential.

The license permits the installation, repair, replacement, alteration, and maintenance of gas or oil burners for domestic and light commercial installations.

For this classification, a domestic or light commercial burner is one consuming five gallons of fuel or less per hour or serving a system with a total heating load not exceeding 500,000 BTUs.

The permitted scope includes piping for petroleum-based and alternative fuels, including tanks and related equipment. It also includes LP gas supplied by containers, natural-gas piping, approved gas applications, gas-utilization equipment, and related accessories within the B-2 limitations.

The B-2 classification includes sheet-metal work when that work pertains to the limited scope of the credential. The license does not provide unrestricted authority for plumbing, cooling, heating, mechanical, or fuel work outside the B-2 classification.

Applicants must complete a registered apprenticeship program or demonstrate equivalent experience and training accepted by the Connecticut Department of Consumer Protection.

Applicants relying on equivalent experience, training, or an out-of-state credential must provide sufficient documentation for Connecticut to evaluate their qualifications. Previous employment or licensing elsewhere does not automatically establish eligibility.

PSI administers the examination but does not determine whether an applicant qualifies for the B-2 license. The Department of Consumer Protection reviews the application and authorizes eligible candidates to test.

After passing the examination, the applicant must complete any remaining licensing requirements and submit the applicable state charges. A passing examination score alone does not authorize regulated work.

A B-2 journeyperson license is separate from a contractor license and business registration. A journeyperson who plans to operate a business, contract directly with customers, or assume contractor-level responsibility may need an appropriate contractor license and other business credentials.

Reference Books

  • International Mechanical Code, 2021
    This code supports preparation involving mechanical equipment, burner installations, combustion air, fuel systems, chimneys, vents, appliance clearances, accessibility, and general mechanical safety requirements.
  • International Residential Code for One- and Two-Family Dwellings, 2021
    This residential code addresses appliance installation, fuel-gas piping, combustion air, venting, equipment clearances, residential mechanical systems, and requirements for one- and two-family dwellings.
  • International Fuel Gas Code, 2021
    This code covers gas-piping systems, appliance connections, pressure regulators, combustion air, venting, testing, purging, gas-utilization equipment, and fuel-gas safety.
  • NFPA 31: Standard for the Installation of Oil-Burning Equipment, 2011
    This standard covers oil-burning appliances, burners, tanks, fuel piping, controls, combustion air, venting, installation, operation, and related safety requirements.
  • NFPA 54: National Fuel Gas Code Handbook, 2012
    This handbook supports study of natural-gas piping, longest-length sizing, appliance installation, pressure regulation, combustion air, testing, purging, venting, and system safety.
  • NFPA 58: Liquefied Petroleum Gas Code, 2014
    This code addresses LP-gas containers, regulators, piping, equipment, separation distances, storage, handling, installation, testing, operation, and safety.

Exam Room Approved Books

  • International Mechanical Code, 2021
    Allowed for mechanical equipment, burner installation, combustion-air, chimney, vent, clearance, accessibility, and fuel-system questions.
  • International Residential Code for One- and Two-Family Dwellings, 2021
    Allowed for residential mechanical systems, appliance installation, fuel-gas piping, combustion air, clearances, and venting.
  • International Fuel Gas Code, 2021
    Allowed for gas piping, appliance connections, regulators, testing, purging, combustion air, venting, and gas-utilization equipment.
  • NFPA 31: Standard for the Installation of Oil-Burning Equipment, 2011
    Allowed for oil burners, fuel tanks, oil piping, controls, combustion air, venting, installation, and equipment operation.
  • NFPA 54: National Fuel Gas Code Handbook, 2012
    Allowed for natural-gas piping, longest-length sizing, appliance installation, regulators, testing, purging, combustion air, and venting.
  • NFPA 58: Liquefied Petroleum Gas Code, 2014
    Allowed for LP-gas containers, piping, regulators, equipment, separation distances, storage, handling, testing, and safety.

Test Information and Study Materials

Build a study schedule around the major examination subjects. Give substantial attention to fuel-gas systems, oil burners, natural gas, and liquefied petroleum gas because those areas represent a significant portion of the test.

Create a reference map showing which book supports each subject. Use the International Fuel Gas Code and NFPA 54 for natural-gas and general fuel-gas questions, NFPA 58 for LP-gas topics, and NFPA 31 for oil-burning equipment.

Use the mechanical and residential codes for equipment location, appliance installation, clearances, combustion air, chimneys, vents, and building-related mechanical requirements.

Practice gas-pipe sizing with the longest-length method. Review connected appliance demand, developed piping length, operating pressure, pipe material, table selection, and minimum capacity.

For oil-burning equipment, study tanks, piping, filters, pumps, nozzles, ignition components, combustion air, draft, controls, venting, testing, and maintenance. Practice locating requirements directly in NFPA 31.

Review burner control sequences and safety devices. Understand how thermostats, primary controls, ignition systems, flame detection, motors, valves, limits, and emergency switches interact during startup, operation, and shutdown.

Complete timed practice sessions using only the six books included in this package. Answer familiar questions first, mark lengthy searches, and return to difficult items after completing the remaining questions.

How 1 Exam Prep Helps You Reach Your Goal

1 Exam Prep helps Connecticut B-2 candidates organize the approved technical references needed for open-book journeyperson examination preparation. This package brings the six listed exam-room books together in one focused collection.

The references support trade-focused review of fuel-gas systems, oil-burning equipment, natural gas, liquefied petroleum gas, piping, valves, burner controls, appliances, combustion air, venting, testing, maintenance, and safety.

An organized study process can make a multi-book examination easier to manage. Review one content area at a time, select the most relevant reference, locate the supporting requirement, and return to the books when reviewing missed practice questions.

Reference-navigation practice is especially important for a 90-minute open-book examination. Candidates who understand the purpose and organization of each code can spend less time searching and more time interpreting questions.

This package does not guarantee a passing score, examination eligibility, state approval, or license issuance. Results depend on the candidate’s qualifications, apprenticeship, experience, technical knowledge, preparation, reference familiarity, and examination performance.

FAQ Section

Which books are included in this package?

The package includes the 2021 International Mechanical Code, the 2021 International Residential Code, the 2021 International Fuel Gas Code, NFPA 31 from 2011, the 2012 NFPA 54 Handbook, and NFPA 58 from 2014.

Are all included books allowed into the B-2 examination?

Yes. This package contains the six references identified for use during the Connecticut B-2 open-book trade examination, subject to current testing-center rules.

Is the Connecticut B-2 examination open book?

Yes. The Connecticut Limited Gas and Oil Burner Journeyperson examination is open book.

How many questions are on the B-2 examination?

The examination contains 40 questions and allows one and one-half hours for completion.

What score is required to pass?

A minimum score of 70 percent is required.

Can the references be highlighted and tabbed?

The books may be highlighted, underlined, annotated, or indexed before testing. Permanent tabs are permitted, but temporary or repositionable tabs are not allowed.

Can candidates write in the books during the examination?

No. Candidates may not write in their references during the examination.

Are the books already highlighted and tabbed?

No highlighting or tabbing service is identified as included with this standard Books Allowed into Exam Package.

Does this package include additional study books?

No. This product contains the six references identified for exam-room use. Additional oil-burner study books are not included.

Does a B-2 applicant take a Business and Law exam?

The B-2 is a journeyperson credential. The contractor Business and Law examination is not identified as part of the B-2 journeyperson examination.

What work does the B-2 license cover?

The license covers qualifying installation, repair, replacement, alteration, and maintenance of gas and oil burners for domestic and light commercial applications within Connecticut’s stated limitations.

What qualification is required?

Applicants must complete a registered apprenticeship program or demonstrate equivalent experience and training accepted by Connecticut.

Does this package include Application Service?

No. Application Service is not included. Candidates are responsible for completing the Connecticut application and providing the required supporting records.

Are application and examination fees included?

No. State application fees, PSI examination charges, licensing fees, and other third-party costs are not included.

Does purchasing the package guarantee examination approval?

No. Connecticut determines eligibility based on the applicant’s apprenticeship, experience, training, and supporting documentation.

Does passing the examination automatically issue the license?

No. Passing the B-2 examination is one part of the licensing process. The applicant must complete all remaining Connecticut requirements before the license can be issued.