Prepare for the Connecticut Limited Gas and Oil Burner Journeyperson (B-2) examination with a coordinated collection of mechanical, residential, fuel-gas, oil-burning, natural-gas, liquefied petroleum gas, and burner-service references. This package combines the books used for open-book exam preparation with an additional oil-burner study resource.
The Connecticut B-2 examination evaluates knowledge of gas and oil burner installation, repair, replacement, alteration, and maintenance in domestic and light commercial applications. Candidates should understand fuel-gas systems, natural gas, liquefied petroleum gas, oil burners, controls, piping, valves, equipment, chimneys, flues, vents, maintenance procedures, testing methods, and safe work practices.
This package includes the International Mechanical Code, 2021, International Residential Code for One- and Two-Family Dwellings, 2021, International Fuel Gas Code, 2021, NFPA 31: Standard for the Installation of Oil-Burning Equipment, 2011, NFPA 54: National Fuel Gas Code Handbook, 2012, and NFPA 58: Liquefied Petroleum Gas Code, 2014.
The package also includes Residential Oil Burners, 3rd Edition. This additional study reference supports preparation involving oil-burner components, fuel delivery, pumps, filters, nozzles, ignition systems, combustion, draft, controls, testing instruments, maintenance, and troubleshooting.
Each reference serves a different purpose. The mechanical and residential codes address equipment installation, combustion air, venting, appliance clearances, access, fuel systems, and residential requirements. The International Fuel Gas Code and NFPA 54 support preparation involving natural-gas piping, appliance connections, pressure regulation, testing, purging, combustion air, and venting.
NFPA 31 focuses on oil-burning appliances, tanks, fuel piping, burners, controls, combustion air, and venting. NFPA 58 addresses LP-gas containers, regulators, piping, separation distances, storage, handling, equipment installation, and system safety.
The Connecticut B-2 trade examination is open book and timed. Candidates should be familiar with the organization of every exam-room reference before test day. Knowing which book covers a subject can reduce unnecessary searching and leave more time for code interpretation, piping questions, and technical calculations.
This Connecticut B-2 exam book package is designed for apprentices, burner technicians, heating professionals, fuel-gas installers, oil-heating technicians, service professionals, and qualified applicants pursuing the Limited Gas and Oil Burner Journeyperson license.
This product contains the listed exam and study books. Online course access, highlighting and tabbing, Application Service, examination registration, government fees, book rental, and professional licensing approval are not identified as included.
The Connecticut B-2 Limited Gas and Oil Burner Journeyperson examination contains 40 questions. Candidates receive one and one-half hours to complete the examination and must earn a minimum score of 70 percent.
The published examination content outline includes:
Fuel-gas systems are the largest individual examination category. Candidates should review approved piping materials, pipe sizing, system pressure, regulators, appliance connections, shutoff valves, sediment traps, testing, purging, combustion air, venting, and installation requirements.
Natural-gas questions may involve fuel characteristics, piping capacity, developed length, pressure regulation, equipment connections, appliance installation, leak testing, combustion air, and venting. Candidates should understand how appliance input, pipe material, system pressure, and piping length affect gas-system design.
Liquefied petroleum gas questions may cover containers, regulators, piping, equipment, separation distances, storage, handling, testing, installation, and safety. Candidates should recognize that LP-gas requirements differ from natural-gas requirements and use the correct reference for each fuel type.
Oil-burner questions may involve fuel storage, supply piping, filters, pumps, nozzles, burner motors, ignition components, combustion, draft, controls, venting, testing, adjustment, and maintenance. Candidates should understand how nozzle size, spray pattern, pump pressure, combustion air, ignition, and draft affect burner operation.
General-knowledge questions may address combustion principles, tools, materials, basic electricity, burner components, equipment operation, heat, draft, safety, and common trade terminology. Candidates should understand the relationship among fuel, air, ignition, flame, draft, heat transfer, and venting.
Control questions may involve thermostats, transformers, relays, primary controls, limit devices, flame-safeguard systems, ignition components, gas valves, motors, and emergency switches. Candidates should recognize the function of each control and understand the normal sequence of burner operation.
Equipment questions may address furnaces, boilers, burners, combustion chambers, heat exchangers, tanks, regulators, valves, venting systems, and related accessories. Preparation should include appliance locations, service access, clearances, combustion air, and equipment safety.
Piping and valve questions may involve approved materials, sizing, fittings, supports, joining methods, shutoff devices, regulators, oil-supply lines, gas piping, and equipment connections. Improper piping design or installation can cause leakage, inadequate fuel delivery, poor burner performance, or unsafe operation.
Testing and maintenance questions may include leak testing, smoke testing, combustion analysis, draft measurement, equipment inspection, cleaning, troubleshooting, startup, shutdown, and verification of safe operation.
The Connecticut Limited Gas and Oil Burner Journeyperson (B-2) trade examination is an open-book test. Candidates are responsible for bringing their own authorized references to the examination center.
The examination provides 90 minutes for 40 questions. That allows slightly more than two minutes per question. Candidates who are unfamiliar with the references may spend too much time searching and leave insufficient time for pipe sizing, code interpretation, or detailed equipment questions.
Reference materials may be highlighted, underlined, annotated, or indexed before the examination. Permanent tabs are permitted. Temporary tabs, including removable or repositionable notes, are not allowed.
Candidates may not write in the references during the examination. Loose papers and unauthorized attached materials are not permitted. Questions and answers written into the books must be removed before entering the testing room.
A silent, nonprinting, non-programmable calculator may be used during the examination. Candidates should practice using an approved calculator for fuel-gas sizing and other trade calculations.
For gas-pipe sizing questions, candidates must use the longest-length method. Preparation should include determining the connected appliance load, measuring the longest developed piping length, selecting the correct fuel, pressure, and pipe-material table, and choosing a pipe size with sufficient capacity.
Use the International Mechanical Code for questions involving mechanical equipment, appliance installation, combustion air, fuel systems, chimneys, vents, clearances, service access, and safety.
Use the International Residential Code for mechanical and fuel-gas requirements involving one- and two-family dwellings. Important areas include appliance locations, combustion air, residential fuel piping, equipment clearances, venting, and installation requirements.
Use the International Fuel Gas Code for gas-piping systems, regulators, appliance connections, testing, purging, combustion air, venting, gas-utilization equipment, and fuel-gas safety.
Use NFPA 31 for oil-burning appliances, storage tanks, oil piping, burners, controls, combustion air, venting, installation, and operation. Become familiar with the organization of the standard and the location of equipment-specific requirements.
Use NFPA 54 for natural-gas piping, longest-length sizing, appliance installation, pressure regulation, combustion air, venting, testing, and purging. Use NFPA 58 for LP-gas containers, regulators, piping, equipment, separation distances, storage, handling, and safety.
Develop a consistent reference-search process. Identify the primary subject in the question, choose the most relevant code or standard, use the index or table of contents, and review the complete applicable provision. Read definitions, exceptions, table headings, notes, and cross-references before selecting an answer.
The Connecticut Department of Consumer Protection regulates occupational trade licenses and determines examination eligibility. PSI administers the B-2 examination after the state approves the applicant.
The B-2 is a journeyperson-level license. The separate Business and Law examination required for contractor classifications is not identified as part of the B-2 journeyperson examination.
This exam book package does not include Application Service, application preparation, PSI registration, examination fees, licensing fees, or submission of licensing documents.
The Connecticut B-2 Limited Gas and Oil Burner Journeyperson license authorizes qualifying gas and oil burner work within the limits established for the classification.
The license permits the installation, repair, replacement, alteration, and maintenance of gas or oil burners for domestic and light commercial installations.
For this classification, a domestic or light commercial burner is one consuming five gallons of fuel or less per hour or serving a system with a total heating load not exceeding 500,000 BTUs.
The permitted scope includes piping for petroleum-based fuels and alternative fuels, including tanks and related equipment. It also includes liquefied petroleum gas supplied by containers, natural-gas piping, approved gas applications, gas-utilization equipment, and accessories within the license limits.
The B-2 classification includes sheet-metal work when that work pertains to the limitations of the credential. The license does not provide unlimited authority for heating, cooling, plumbing, mechanical, or fuel work outside the defined B-2 scope.
Applicants must complete a registered apprenticeship program or demonstrate equivalent experience and training accepted by the Connecticut Department of Consumer Protection.
Applicants using an equivalent-experience or out-of-state pathway must provide sufficient documentation for Connecticut to evaluate their classroom training, on-the-job experience, employment history, and prior credentials.
PSI administers the examination but does not determine whether an applicant qualifies for licensure. The Department of Consumer Protection reviews the application and authorizes eligible candidates to test.
After passing the examination, the applicant must complete the remaining licensing requirements and submit the applicable state charges. A passing score alone does not authorize the individual to perform regulated work.
A B-2 journeyperson license is separate from a contractor license and business registration. A journeyperson who plans to operate a contracting business or assume contractor-level responsibility may need an appropriate contractor credential and additional business registrations.
Residential Oil Burners, 3rd Edition is included as an additional study reference and is not identified as an exam-room book.
Build a study schedule around the ten examination categories. Give substantial attention to fuel-gas systems, oil burners, natural gas, and liquefied petroleum gas because these areas represent most of the examination questions.
Create a reference map showing which book supports each subject. Use the International Fuel Gas Code and NFPA 54 for gas-system questions, NFPA 58 for LP-gas topics, NFPA 31 for oil-burning equipment, and the mechanical and residential codes for building-related installation requirements.
Practice gas-pipe sizing using the longest-length method. Review connected appliance loads, developed piping length, system pressure, pipe material, table selection, and minimum required capacity.
For oil-burning equipment, study fuel tanks, piping, filters, pumps, nozzles, ignition systems, combustion air, draft, venting, controls, testing, and maintenance. Use Residential Oil Burners to strengthen practical understanding before completing timed work with the exam-room references.
Review burner control sequences and safety devices. Understand how thermostats, primary controls, flame detection, ignition components, motors, valves, limits, and emergency switches interact during startup, normal operation, and shutdown.
Practice locating chimney, flue, vent, and combustion-air requirements. Pay attention to fuel type, appliance input, equipment category, building volume, vent materials, connector sizing, clearances, and termination conditions.
Complete timed practice sessions using only the six books permitted in the examination room. Answer familiar questions first, mark lengthy code searches, and return to difficult questions after completing the remaining items.
1 Exam Prep helps Connecticut B-2 candidates organize the references needed for open-book journeyperson examination preparation. This package combines the six exam-room books with an additional oil-burner study reference.
The books support trade-focused review of gas systems, oil-burning equipment, natural gas, liquefied petroleum gas, controls, equipment, piping, valves, chimneys, vents, testing, maintenance, and burner safety.
An organized study approach can make a multi-book examination easier to manage. Candidates can review one subject at a time, identify the most useful reference, locate supporting requirements, and return to the books when reviewing missed practice questions.
Reference-navigation practice is especially important during a 90-minute open-book examination. Familiarity with chapters, indexes, definitions, tables, and code organization can help candidates use testing time more effectively.
This package does not guarantee a passing score, examination eligibility, state approval, or license issuance. Results depend on the candidate’s qualifications, training, trade experience, technical knowledge, preparation, reference familiarity, and examination performance.
The package includes seven books covering mechanical requirements, residential systems, fuel gas, oil-burning equipment, natural gas, LP gas, and residential oil-burner service.
Yes. The Connecticut Limited Gas and Oil Burner Journeyperson examination is open book.
The examination contains 40 questions and allows one and one-half hours for completion.
A minimum score of 70 percent is required.
No. Six books are identified for exam-room use. Residential Oil Burners, 3rd Edition is included as an additional study reference.
The references may be highlighted, underlined, annotated, or indexed before testing. Permanent tabs are permitted, but temporary tabs are not allowed.
No. Candidates may not write in their references during the examination.
The B-2 is a journeyperson license. The contractor Business and Law examination is not identified as part of the B-2 journeyperson examination.
The license covers qualifying gas and oil burner installation, repair, replacement, alteration, and maintenance for domestic and light commercial applications within Connecticut’s stated limits.
Applicants must complete a registered apprenticeship program or demonstrate equivalent experience and training accepted by Connecticut.
No. Application Service is not identified as included with this exam book package.
No. State application fees, PSI examination charges, licensing fees, and other third-party costs are not included.
No. Connecticut determines eligibility based on the applicant’s apprenticeship, experience, training, and supporting documentation.
No. Passing the examination is one part of the licensing process. The applicant must complete all remaining Connecticut requirements before the license can be issued.