Nevada Masonry Contractor (C-18) Exam Book Package

Nevada Masonry Contractor (C-18) Exam Book Package

Regular price $595.00
Sale price $595.00 Regular price $695.00
Sale Sold out
Shipping calculated at checkout.
Choose Your Option

CALL TO ASK ABOUT FINANCIAL ASSISTANCE

  • image-right
Customer Reviews
View full details

Nevada Masonry Contractor (C-18) Exam Book Package

Prepare for the Nevada Masonry Contractor (C-18) examination with a focused exam book package covering masonry codes, brick and block construction, structural masonry requirements, jobsite safety, materials, mortar, reinforcement, wall systems, and practical masonry methods. This package includes the International Building Code, 2018, ACI 530/530.1-13 (2011 or 2013): Building Code Requirements and Specification for Masonry Structures and Companion Commentaries, Code of Federal Regulations - 29 CFR Part 1926 (OSHA), and Modern Masonry - Brick, Block, Stone, Clois E. Kicklighter, 10th edition.

The Nevada C-18 Masonry examination is an open-book test. The International Building Code, 2018 and ACI 530/530.1-13 are the exam-room references included with this package. Candidates should become comfortable navigating these books before test day so they can locate code requirements involving masonry construction, structural walls, reinforcement, materials, installation, and related building requirements efficiently.

The package also includes two supplemental study references that are not allowed inside the examination room: Code of Federal Regulations - 29 CFR Part 1926 (OSHA) and Modern Masonry - Brick, Block, Stone, Clois E. Kicklighter, 10th edition. These books are intended to strengthen practical trade knowledge and construction-safety preparation before the examination.

Nevada's C-18 Masonry classification applies to specialty masonry work involving materials such as brick, baked clay products, rough-cut and dressed stone, artificial stone, precast blocks, and structural glass brick or block. Candidates should understand both the hands-on construction practices of masonry and the code requirements that govern structural masonry systems.

This combination of exam-room and study-only references supports a balanced preparation strategy. Use the International Building Code and ACI masonry requirements for repeated code-navigation practice, while using Modern Masonry and OSHA to strengthen practical knowledge, construction methods, terminology, tools, materials, and jobsite safety.

What You Get

  • International Building Code, 2018 — included as an exam-room reference for Nevada C-18 Masonry Contractor preparation.
  • ACI 530/530.1-13 (2011 or 2013): Building Code Requirements and Specification for Masonry Structures and Companion Commentaries — included as an exam-room structural masonry reference.
  • Code of Federal Regulations - 29 CFR Part 1926 (OSHA) — supplemental construction-safety study reference. This book is not allowed inside the examination room.
  • Modern Masonry - Brick, Block, Stone, Clois E. Kicklighter, 10th edition — supplemental trade study reference covering practical masonry materials, methods, tools, and construction techniques. This book is not allowed inside the examination room.

Exam Details

The Nevada Masonry Contractor (C-18) trade examination evaluates knowledge associated with masonry construction and the responsibilities of contractors performing masonry work within the classification.

Candidates should prepare for questions involving brick, concrete masonry units, stone, structural masonry, mortar, grout, reinforcement, wall construction, openings, anchors, flashing, structural requirements, tools, estimating concepts, and jobsite safety.

The International Building Code supports preparation involving building-code requirements that affect masonry construction. Candidates should become familiar with the organization of the code and understand how general building provisions interact with requirements for masonry walls, structural systems, fire-resistance concepts, building components, and other construction conditions.

ACI 530/530.1 provides more specialized structural masonry information. Candidates should understand how to locate requirements involving masonry materials, reinforcement, grout, structural walls, construction specifications, quality, and related masonry provisions.

Practical masonry knowledge is equally important. Modern Masonry can help candidates review brick and block construction, stone masonry, mortar, bonding patterns, tools, layout, wall construction, reinforcement, and installation procedures. Because this book is not allowed inside the examination room, candidates should use it to build understanding that can be applied from memory.

Safety should be incorporated throughout preparation. Masonry work can involve scaffolds, ladders, material handling, cutting equipment, silica-producing operations, masonry saws, lifting, wall construction, overhead hazards, and other conditions addressed through construction-safety practices.

Open Book Test

The Nevada Masonry Contractor (C-18) examination is an open-book test with specific reference materials used for exam-room navigation.

The exam-room references included with this package are:

  • International Building Code, 2018
  • ACI 530/530.1-13 (2011 or 2013): Building Code Requirements and Specification for Masonry Structures and Companion Commentaries

The following books are included for study but are not allowed inside the examination room:

  • Code of Federal Regulations - 29 CFR Part 1926 (OSHA)
  • Modern Masonry - Brick, Block, Stone, Clois E. Kicklighter, 10th edition

Open-book testing still requires preparation. Candidates should know which reference is most likely to contain the answer before they begin searching. A general building-code question may lead to the International Building Code, while a technical structural masonry question may be more directly addressed through ACI 530/530.1.

Practice identifying keywords before opening the references. If a question involves reinforcement, grout, masonry walls, anchors, or structural requirements, determine which reference and topic should be checked first. This can reduce time spent searching unrelated sections.

The study-only books should be approached differently. Use Modern Masonry and OSHA to understand procedures, materials, tools, trade terminology, and safe work practices, then practice answering related questions without the books open.

Licensing Steps

The Nevada C-18 trade examination is one part of the contractor licensing process. Applicants must complete the applicable Nevada contractor licensing requirements in addition to preparing for the masonry examination.

  1. Confirm the C-18 classification. Make sure the masonry work the business intends to perform falls within the Nevada C-18 Masonry classification.
  2. Identify the qualifying individual. The contractor license application must identify the individual who will qualify on behalf of the business.
  3. Prepare qualifying experience information. Organize applicable work history involving brick, block, stone, structural masonry, mortar, grout, reinforcement, layout, or related masonry responsibilities.
  4. Submit the contractor license application. Complete the required business, qualifying individual, experience, financial, and supporting information.
  5. Wait for application and experience review. Examination eligibility is established after the application is submitted and the qualifying experience is reviewed.
  6. Receive examination eligibility. The qualifying individual can schedule the applicable examinations after authorization is issued.
  7. Prepare for the C-18 trade examination. Study masonry materials, construction methods, structural requirements, code navigation, and safety.
  8. Prepare for Nevada business and law. Contractor applicants are also subject to the applicable business and law examination requirements unless a waiver applies.
  9. Complete the required examinations. Satisfy the examinations associated with the requested classification.
  10. Complete remaining licensing requirements. Finish all other applicable requirements before the Nevada contractor license is issued.

State Requirements

Nevada designates C-18 Masonry as a specialty contractor classification. A contractor holding this classification may perform qualifying masonry work involving the selection, cutting, and laying of materials such as brick, other baked clay products, rough-cut and dressed stone, artificial stone, precast blocks, and structural glass brick or block.

The work may involve materials laid at random or in courses and may be performed with or without mortar, depending on the type of masonry installation.

The C-18 classification requires specialized trade knowledge because masonry systems combine material selection, layout, structural considerations, installation methods, reinforcement, mortar or grout, and finished workmanship. A candidate should understand not only how individual units are placed but also how the completed wall or masonry assembly functions.

Candidates should study masonry construction as a complete system. Foundations or supports, wall layout, coursing, bonds, openings, lintels, reinforcement, anchors, control concepts, flashing, mortar, grout, and weather conditions can all affect the performance and appearance of finished masonry.

Nevada contractor licensing also involves requirements beyond the trade examination. The qualifying individual must complete the applicable examination process and the applicant must satisfy the other licensing requirements associated with the requested classification.

Reference Books

  • International Building Code, 2018
    This exam-room reference supports preparation involving building-code requirements affecting masonry construction, structural systems, walls, fire-resistance concepts, building components, and related construction provisions.
  • ACI 530/530.1-13 (2011 or 2013): Building Code Requirements and Specification for Masonry Structures and Companion Commentaries
    This exam-room reference supports technical study involving structural masonry requirements, masonry materials, reinforcement, grout, construction specifications, wall systems, quality requirements, and related structural provisions.
  • Code of Federal Regulations - 29 CFR Part 1926 (OSHA)
    This supplemental study reference supports construction-safety preparation involving scaffolds, ladders, personal protective equipment, material handling, tools, masonry operations, and other jobsite hazards. It is not allowed inside the examination room.
  • Modern Masonry - Brick, Block, Stone, Clois E. Kicklighter, 10th edition
    This supplemental trade reference supports study involving brick, block, stone, mortar, masonry tools, layout, bonding, construction techniques, wall systems, reinforcement, and practical masonry procedures. It is not allowed inside the examination room.

Exam Room Approved Books

  • International Building Code, 2018
    This code reference is included for exam-room use during the Nevada C-18 Masonry Contractor examination.
  • ACI 530/530.1-13 (2011 or 2013): Building Code Requirements and Specification for Masonry Structures and Companion Commentaries
    This structural masonry reference is included for exam-room use during the Nevada C-18 examination.

OSHA 29 CFR Part 1926 and Modern Masonry - Brick, Block, Stone, 10th edition are study-only references and are not allowed inside the examination room.

Test Information and Study Materials

A strong Nevada C-18 study plan should combine practical masonry knowledge, structural masonry requirements, building-code navigation, and construction-safety preparation.

Brick and Block Construction should include unit selection, layout, coursing, bonding, cutting, placement, joints, alignment, and workmanship. Candidates should understand how individual units become part of a complete wall or structure.

Mortar and Grout should be reviewed for their roles in masonry construction. Candidates should understand the difference between mortar and grout, how each is used, and why proper placement and consistency matter.

Reinforcement should receive dedicated attention. Structural masonry can use reinforcing steel, anchors, ties, and related components to improve performance and connect masonry to surrounding construction.

Stone Masonry should be studied for material selection, cutting, placement, bonding, support, and finishing. Stone work can differ substantially from standard concrete masonry or brick construction, so candidates should understand the basic trade principles involved.

Wall Layout and Construction should include dimensions, corners, openings, lines, levels, plumb conditions, coursing, and proper sequencing. Accurate layout is essential because small errors can compound as wall height increases.

Openings and Structural Features should include lintels, supports, reinforcement around openings, bearing conditions, and the way doors, windows, or other penetrations affect masonry systems.

Flashing and Moisture Control should be reviewed as part of wall performance. Candidates should understand how moisture can enter masonry construction and why proper detailing is important.

Structural Masonry Requirements should be practiced through ACI 530/530.1. Learn how the reference is organized and where requirements involving materials, reinforcement, structural walls, specifications, and construction quality can be found.

Building Code Requirements should be practiced through the International Building Code. Candidates should become familiar with the organization of the code and the relationship between general building requirements and masonry construction.

Masonry Tools and Equipment should include tools used for mixing, cutting, laying, aligning, measuring, striking joints, and handling masonry materials. Candidates should understand both the purpose and safe use of common equipment.

Scaffolds and Ladders are important safety subjects because masonry work frequently takes place above ground level. Review safe access, working platforms, fall hazards, and equipment conditions through OSHA study.

Material Handling deserves attention because masonry units, mortar materials, reinforcing steel, and equipment can be heavy. Safe storage, lifting, movement, and staging contribute to both productivity and jobsite safety.

Code-navigation practice should be timed. Choose a masonry question, identify the central subject, decide whether the International Building Code or ACI 530/530.1 is the better starting point, and then locate the requirement efficiently.

For the books that are not allowed in the exam, use active recall. Review a chapter or topic, close the reference, and explain the procedure or answer practice questions without looking back at the text.

Practice questions should be used to identify weak areas. If structural masonry questions are difficult, spend additional time with ACI 530/530.1. If general building-code questions take too long, improve International Building Code navigation. If practical masonry questions are weak, return to Modern Masonry. If safety questions are challenging, increase OSHA review.

How 1 Exam Prep Helps You Reach Your Goal

1 Exam Prep supports Nevada Masonry Contractor candidates through organized study guidance, trade-focused review, practice-oriented preparation, exam-reference navigation, and a structured approach to C-18 masonry topics.

This Nevada C-18 Exam Book Package combines the International Building Code, 2018 and ACI 530/530.1-13 with supplemental study references covering practical masonry and construction safety.

The exam-room references can be used throughout preparation to develop better navigation habits. Candidates can practice deciding which book applies to a question and then locating the appropriate building-code or structural masonry requirement.

Modern Masonry supports trade-focused review involving brick, block, stone, mortar, layout, wall construction, tools, and installation techniques. OSHA supports preparation involving scaffolds, ladders, material handling, protective equipment, tools, and other construction hazards.

1 Exam Prep encourages candidates to combine code navigation with actual trade knowledge. Understanding the masonry system first makes it easier to determine where a technical answer should be found and reduces unnecessary searching.

Practice-oriented preparation also helps identify weaker subjects. Candidates can devote additional study time to structural requirements, practical masonry methods, safety, or code navigation based on their performance.

The goal is to help candidates approach the Nevada Masonry Contractor (C-18) examination with stronger trade knowledge, greater familiarity with the exam-room references, and a more organized study strategy without guaranteeing an examination result or licensing approval.

What books are included in the Nevada C-18 Masonry Contractor Exam Book Package?

The package includes International Building Code, 2018, ACI 530/530.1-13, Code of Federal Regulations - 29 CFR Part 1926 (OSHA), and Modern Masonry - Brick, Block, Stone, Clois E. Kicklighter, 10th edition.

Is the Nevada C-18 Masonry examination open book?

Yes. The Nevada C-18 Masonry Contractor examination is an open-book test using the approved exam-room references.

Which books are allowed inside the Nevada C-18 examination?

The International Building Code, 2018 and ACI 530/530.1-13 are the exam-room references included with this package.

Is OSHA 29 CFR Part 1926 allowed inside the C-18 exam?

No. OSHA 29 CFR Part 1926 is included as a supplemental construction-safety study reference and is not allowed inside the examination room.

Is Modern Masonry allowed inside the examination?

No. Modern Masonry - Brick, Block, Stone, Clois E. Kicklighter, 10th edition is a study-only reference and is not allowed inside the examination room.

What does the Nevada C-18 Masonry classification cover?

The classification covers qualifying masonry work involving brick, baked clay products, rough-cut and dressed stone, artificial stone, precast blocks, structural glass brick or block, and related masonry construction.

Why is ACI 530/530.1 included?

ACI 530/530.1 supports preparation involving structural masonry requirements, materials, reinforcement, grout, specifications, wall systems, and other technical masonry provisions.

Why is the International Building Code included?

The International Building Code supports preparation involving broader building-code requirements that affect masonry construction and structural building systems.

Why is Modern Masonry included if it cannot be used during the exam?

Modern Masonry supports practical trade preparation involving brick, block, stone, mortar, tools, layout, wall construction, and masonry methods that candidates should understand before testing.

How should I study the exam-room references?

Practice identifying whether a question belongs in the International Building Code or ACI 530/530.1, then use the index, table of contents, headings, and cross-references to locate the applicable requirement.

How should I study the books that are not allowed into the exam?

Use active recall. Review the material, close the book, and answer practice questions or explain the masonry procedure or safety concept from memory.

Does this package guarantee a passing score?

No. The package provides exam-room and supplemental study references to support organized preparation. Examination results depend on each candidate's experience, trade knowledge, study, and performance.