Nevada Studs of Sheet Metal Contractor (C-17F) Books & Course Rental - Exam Room Approved

Nevada Studs of Sheet Metal Contractor (C-17F) Books & Course Rental - Exam Room Approved

Regular price $989.00
Sale price $989.00 Regular price $1,289.00
Sale Sold out
Shipping calculated at checkout.
Choose Your Option

CALL TO ASK ABOUT FINANCIAL ASSISTANCE

  • image-right
1 Exam Prep Book Rental Deposits Refunded $32660 Returned to Students Since January 2025
Customer Reviews
View full details

Nevada Studs of Sheet Metal Contractor (C-17F) Books & Course Rental - Exam Room Approved

Prepare for the Nevada Studs of Sheet Metal Contractor (C-17F) examination with an exam-room-approved books and course rental package built around the references needed for trade exam and Nevada contractor business preparation. This package includes the International Building Code, 2018 and the Construction Business and Law Manual for Nevada, with both books highlighted and tabbed to support organized study and faster reference navigation.

The Nevada C-17F Studs of Sheet Metal trade examination is an open-book test. The International Building Code, 2018 is the exam-room-approved trade reference included in this package. Candidates can use it during preparation to build familiarity with wall assemblies, ceiling construction, fire-resistance provisions, materials, definitions, tables, exceptions, and other building-code topics related to nonstructural sheet metal framing.

The package also includes the Construction Business and Law Manual for Nevada for business and law preparation. Both rental books are highlighted and tabbed, helping candidates organize key sections and practice efficient navigation before test day.

The Nevada C-17F examination contains 20 questions, allows 1 hour for completion, and requires 14 correct answers to pass. The examination consists of 4 Code Requirements questions and 16 Metal Framing Installation questions, making practical metal framing knowledge the largest part of the trade exam.

The Nevada C-17F classification covers the erection and installation of studs made of sheet metal for the framing of ceilings and nonstructural partitioning walls. Candidates should prepare for practical topics involving studs, tracks, layout, openings, ceiling framing, fastening, alignment, and relationships between framing and finished wall or ceiling systems.

The package price is $839 plus a refundable deposit of $150, for a total of $989. It also includes 6 months of course access to support organized trade and contractor business preparation.

Please allow up to 15 business days for book & course rental - exam room approved package orders.

What You Get

  • Included Rental Book: International Building Code, 2018 — highlighted and tabbed.
  • Included Rental Book: Construction Business and Law Manual for Nevada — highlighted and tabbed.
  • Course Access: 6 months of course access.
  • Trade Exam Reference: International Building Code, 2018 is included as the exam-room-approved reference for the C-17F trade examination.
  • Rental Price: $839.
  • Refundable Deposit: $150.
  • Total: $989.

Exam Details

The Nevada C-17F Studs of Sheet Metal examination contains 20 questions. Candidates are given 1 hour to complete the examination and must answer 14 questions correctly to pass.

The examination is divided into the following subject areas:

  • Code Requirements: 4 questions
  • Metal Framing Installation: 16 questions

Metal Framing Installation represents 80 percent of the examination. Candidates should therefore devote most of their study time to practical knowledge of nonstructural sheet metal framing, including studs, tracks, partition layout, ceiling framing, openings, fastening, alignment, and related field procedures.

Code Requirements accounts for 4 questions. The International Building Code, 2018 supports this part of the exam by providing code requirements related to walls, ceilings, fire resistance, materials, assemblies, and other building provisions.

With 20 questions in one hour, candidates have an average of approximately three minutes per question. Effective preparation should combine strong retained trade knowledge with efficient code navigation so time is not lost on unnecessary searches.

Open Book Test

The Nevada C-17F Studs of Sheet Metal trade examination is an open-book test.

The exam-room-approved trade reference included in this rental package is:

  • International Building Code, 2018

The International Building Code included in this package is highlighted and tabbed. Candidates can use the prepared organization during study to become more familiar with major code areas and build a repeatable lookup strategy.

Tabs are most useful when candidates already understand what section they need. Highlighting can help important provisions stand out, but candidates should also know how to use the table of contents, index, definitions, tables, exceptions, and cross-references.

For a question involving wall construction, ceilings, materials, or fire resistance, begin by identifying the subject of the question. Then use the book's organization to narrow the search to the applicable code area.

Because 16 of the 20 examination questions cover Metal Framing Installation, candidates should not expect the code book to answer every question. Practical knowledge remains the main part of the C-17F trade examination.

Licensing Steps

  1. Confirm the C-17F classification. Make sure Studs of Sheet Metal matches the contracting work the business intends to perform.
  2. Identify the qualifying individual. The Nevada contractor application must identify the individual responsible for satisfying the applicable qualification requirements.
  3. Prepare qualifying experience information. Organize the applicable work-history documentation related to sheet metal stud framing.
  4. Submit the contractor license application. Complete the applicable Nevada contractor application and supporting documentation.
  5. Receive examination eligibility. After applicable qualification and application requirements are addressed, proceed with required testing.
  6. Prepare for the C-17F trade examination. Study Metal Framing Installation and Code Requirements while practicing with the highlighted and tabbed International Building Code.
  7. Prepare for contractor business requirements. Study the Construction Business and Law Manual for Nevada and use the included course access to organize business and law preparation.
  8. Complete the applicable examinations. Take the required trade and contractor business examinations.
  9. Complete remaining licensing requirements. Finish the other applicable requirements associated with contractor license issuance.

State Requirements

Nevada identifies C-17F as the Studs of Sheet Metal subclassification.

The classification covers the erection and installation of studs made of sheet metal for the framing of ceilings and nonstructural partitioning walls.

The C-17F classification focuses on nonstructural metal framing rather than structural steel framing. Candidates should understand how sheet metal studs and tracks are used to create partitions and ceiling framing without confusing this work with primary structural members.

Typical C-17F work can involve floor tracks, ceiling tracks, vertical studs, partition layout, framing around openings, ceiling systems, fasteners, alignment, and coordination with gypsum board and other construction components.

Building-code knowledge is also important because wall and ceiling assemblies can be affected by code requirements involving materials, fire resistance, construction methods, and complete assembly performance.

The C-17F trade examination is one part of Nevada contractor licensing. Applicants must also satisfy applicable qualification, application, business, financial, and other licensing requirements before a contractor license is issued.

Reference Books

  • Included Rental Book: International Building Code, 2018
    This highlighted and tabbed exam-room-approved trade reference supports preparation involving wall assemblies, ceilings, fire-resistance provisions, materials, definitions, tables, exceptions, and related building-code requirements relevant to nonstructural metal framing.
  • Included Rental Book: Construction Business and Law Manual for Nevada
    This highlighted and tabbed business reference supports study of Nevada contractor business and law subjects that are part of the broader contractor licensing process.

Exam Room Approved Books

  • International Building Code, 2018
    This highlighted and tabbed reference is included for use during the Nevada C-17F Studs of Sheet Metal trade examination. Candidates should practice using the tabs, highlighted sections, index, table of contents, definitions, and cross-references before test day.

Test Information and Study Materials

A productive Nevada C-17F study plan should place the greatest emphasis on Metal Framing Installation because that subject accounts for 16 of the 20 trade examination questions.

Begin with the major components of a nonstructural metal framing system. Candidates should understand the purpose and relationship of studs, tracks, fasteners, openings, and ceiling framing members.

Layout is one of the fundamental skills involved in sheet metal framing. Candidates should understand how partition locations are established and how top and bottom tracks are aligned before studs are installed.

Accurate measurements are important because errors in layout can affect walls, doors, openings, ceilings, and subsequent finish work.

Stud installation should include placement within tracks, orientation, alignment, spacing concepts, fastening, and coordination with nearby construction.

Track installation should include positioning, alignment, attachment, and the relationship between the tracks and completed wall system.

Openings deserve separate study. Candidates should understand how framing layouts change around doorways and other penetrations and how those conditions affect surrounding studs and tracks.

Ceiling framing is specifically included in the C-17F scope. Review the principles of overhead metal framing and how ceiling members coordinate with surrounding surfaces and partition systems.

Fastening should be understood as part of proper installation. Candidates should recognize how secure connections support alignment and the intended performance of a nonstructural framing system.

Alignment is another important practical subject. A properly framed wall or ceiling depends on accurate layout and consistent positioning of individual members.

Coordination with other trades can also affect sheet metal framing. Partitions and ceilings may interact with doors, gypsum board, mechanical work, electrical systems, and other construction components.

The International Building Code, 2018 should be used regularly during preparation for Code Requirements. Candidates should become comfortable moving through the highlighted and tabbed book rather than waiting until test day to use the reference extensively.

Definitions can influence how a code requirement applies. Practice locating unfamiliar terms before moving deeper into the code.

Tables may contain important information about materials or assemblies. Candidates should practice reading headings, notes, and conditions carefully.

Exceptions may change how a general requirement applies. Always read the surrounding language before selecting an answer.

Cross-references can direct candidates to other sections containing additional provisions. Practice following those references so the process becomes familiar.

Wall assemblies should be included in regular IBC navigation practice because nonstructural partitions can be part of complete wall systems governed by building-code requirements.

Ceiling assemblies should also receive attention because ceiling framing is directly included within the C-17F scope.

Fire-resistance provisions should be studied in relation to complete wall or ceiling assemblies. Candidates should understand that the performance of an assembly can depend on multiple components rather than a single piece of framing.

Materials should be understood from both a practical and code perspective. Candidates should recognize the role of sheet metal studs, tracks, fasteners, and related components in nonstructural framing.

The highlighted and tabbed IBC can support timed lookup drills. Choose a topic such as wall construction, ceilings, fire resistance, or materials and practice locating the applicable section within a limited amount of time.

During these drills, candidates should use both the prepared tabs and normal code-navigation tools. The goal is to recognize where information belongs, not simply memorize tab positions.

Since most C-17F questions focus on practical installation, active recall is also useful. Study an installation sequence and then explain the procedure from memory, including layout, tracks, stud placement, openings, fastening, alignment, and completion.

Mixed practice can help candidates move smoothly between practical trade questions and code-based lookups. Once individual topics are familiar, alternate between Metal Framing Installation and Code Requirements during study sessions.

When a practice question is missed, identify the reason. A missed question may point to weak framing knowledge, unfamiliar terminology, slow IBC navigation, or difficulty interpreting a code provision.

Correcting the underlying problem is more valuable than memorizing a single answer. Strong exam preparation comes from developing a working understanding of the trade and knowing when a reference lookup is necessary.

The Construction Business and Law Manual for Nevada should be used as part of contractor business preparation. Because the book is highlighted and tabbed, candidates can organize important business subjects and build familiarity with the reference while using the included course.

The package includes 6 months of course access, allowing candidates to organize preparation across trade and contractor business topics. A useful approach is to pair course study with reference review, practice questions, active recall, and timed navigation drills.

For each topic, review the course material, study the corresponding reference sections, practice questions, and then test understanding without immediately reopening the book. This approach can help reinforce both knowledge and reference-navigation skills.

Time management should be incorporated into study. Candidates should answer familiar questions efficiently and reserve reference searches for questions where the code can meaningfully confirm the answer.

Please allow up to 15 business days for book & course rental - exam room approved package orders.

How 1 Exam Prep Helps You Reach Your Goal

1 Exam Prep supports Nevada C-17F Studs of Sheet Metal Contractor candidates through organized study guidance, trade-focused review, practice-oriented preparation, reference navigation, and confidence-building study structure.

This exam-room-approved rental package includes the highlighted and tabbed International Building Code, 2018 and Construction Business and Law Manual for Nevada, together with 6 months of course access.

The highlighted and tabbed format helps organize major subjects and can support more efficient reference navigation during study. Candidates can combine the books with course preparation and timed practice to develop a more structured routine.

Trade-focused preparation supports stronger understanding of sheet metal studs, tracks, wall layout, openings, ceiling framing, fastening, alignment, and building-code relationships.

Business-focused preparation helps candidates organize Nevada contractor business and law study using the included manual and course access.

The goal is to help candidates approach the C-17F examination and related Nevada contractor licensing study with stronger knowledge, improved reference familiarity, and better study organization without guaranteeing a passing score or licensing approval.

How many questions are on the Nevada C-17F trade exam?

The Nevada C-17F Studs of Sheet Metal examination contains 20 questions.

How much time is allowed for the C-17F examination?

Candidates are allowed 1 hour to complete the examination.

How many correct answers are required to pass?

Candidates must answer 14 questions correctly to pass the C-17F examination.

Is the Nevada C-17F examination open book?

Yes. The Nevada C-17F trade examination is an open-book test.

Which trade book is included for the exam room?

The International Building Code, 2018 is the exam-room-approved C-17F trade reference included in this rental package.

Is the Nevada business book included?

Yes. The package includes the Construction Business and Law Manual for Nevada.

Are both rental books highlighted and tabbed?

Yes. Both books included in this package are highlighted and tabbed.

How much course access is included?

The package includes 6 months of course access.

What is the price of this rental package?

The package is $839 plus a refundable deposit of $150, for a total of $989.

Is the $150 deposit refundable?

Yes. The $150 deposit is refundable.

How many Metal Framing Installation questions are on the C-17F exam?

Metal Framing Installation accounts for 16 questions.

How many Code Requirements questions are on the C-17F exam?

Code Requirements accounts for 4 questions.

What does the Nevada C-17F classification cover?

The C-17F classification covers the erection and installation of sheet metal studs used for framing ceilings and nonstructural partitioning walls.

Why practice with the highlighted and tabbed IBC before test day?

Regular practice can help candidates become more familiar with major code areas, locate relevant provisions more efficiently, and develop a consistent open-book exam strategy.

How long should I allow for this rental package order?

Please allow up to 15 business days for book & course rental - exam room approved package orders.

Does this rental package guarantee that I will pass the exam?

No. The package provides highlighted and tabbed rental books, course access, and organized preparation support. Exam results depend on each candidate's experience, study, trade knowledge, reference-navigation skills, and performance on test day.