Prepare for the Connecticut Limited Warm Air, Air Conditioning and Refrigeration System Journeyperson (D-2) examination with an Ultimate rental package that combines highlighted and tabbed reference books, a Ductulator, one year of online course access, and Application Service. This package gives candidates an organized way to study technical HVAC subjects while practicing with the same included materials throughout their preparation.
The Connecticut D-2 examination covers warm-air heating, air conditioning, refrigeration systems, fuel-gas systems, ductwork, controls, ventilation, heat pumps, furnaces, chillers, safety, combustion air, and related mechanical knowledge. Candidates must understand practical trade concepts and know how to locate code provisions, technical explanations, sizing information, diagrams, definitions, and tables during a timed open-book examination.
This Ultimate Exam Prep Rental includes the International Mechanical Code, 2021; NFPA 54 National Fuel Gas Code Handbook, 2012; Modern Refrigeration and Air Conditioning, 22nd Edition; a Ductulator; HVAC Duct Construction Standards, Metal and Flexible, 2005, 3rd Edition; and NFPA 58 Liquefied Petroleum Gas Code, 2014.
All included books are highlighted and permanently tabbed before delivery. Important chapters, definitions, mechanical requirements, fuel-gas provisions, refrigeration subjects, duct-construction topics, equipment information, technical tables, and commonly reviewed sections are marked to create a practical starting point for study.
The included online course provides one year of access. Candidates can use the course to review the D-2 examination outline, reinforce trade knowledge, complete practice-oriented preparation, and improve open-book reference-navigation skills. Application Service is also included to assist with organizing the applicable Connecticut D-2 journeyperson license application.
The package price is $2,315. A refundable deposit of $750 is required for the rental books, making the total due today $3,065. The $750 deposit is fully refundable when the books are returned within the rental period in similar condition.
Please allow up to 15 business days for ultimate book package orders.
Package Price: $2,315
Refundable Deposit: $750
Total Due Today: $3,065
The $750 deposit is fully refundable when the books are returned within the rental period in similar condition.
The Connecticut Limited Warm Air, Air Conditioning and Refrigeration System Journeyperson (D-2) examination contains 60 questions. Candidates are allowed two hours to complete the examination, and a minimum score of 70 percent is required to pass.
The D-2 examination content outline includes the following categories:
Fuel-gas systems are the largest examination category, accounting for 10 of the 60 questions. Candidates should understand fuel-gas piping, sizing, pressure, regulators, appliance connections, testing, combustion air, venting, and related installation and safety principles.
Gas-pipe sizing questions require use of the longest-length method. Candidates should practice identifying system demand, selecting the correct table, determining the longest measured length, and applying that length consistently when sizing branches within the system.
Refrigerants and refrigeration account for eight questions. Preparation should include refrigeration-cycle principles, compressors, condensers, evaporators, metering devices, refrigerants, pressure-temperature relationships, system operation, charging concepts, maintenance, and troubleshooting.
Ducts account for six questions. Candidates should review duct sizing, airflow, friction rate, velocity, fittings, construction, materials, reinforcement, sealing, supports, and distribution-system performance. The included Ductulator and duct-construction standard support preparation for these subjects.
Heating and cooling principles and air-conditioning and heat-pump equipment each account for five questions. Candidates should understand heat transfer, sensible and latent heat, airflow, equipment operation, heating and cooling cycles, heat-pump functions, and common system components.
Furnaces and heaters and safety each account for four questions. Controls and ventilation and exhaust each account for three questions. Candidates should also review chimneys, flues, vents, combustion air, chillers, insulation, testing, balancing, machinery rooms, hangers, supports, sound, vibration, and seismic control.
With 120 minutes available for 60 questions, candidates have an average of two minutes per question. This time includes reading the question, identifying the subject, choosing the appropriate reference, locating the supporting information, and selecting an answer.
The Connecticut D-2 Limited Warm Air, Air Conditioning and Refrigeration System Journeyperson examination is an open-book test. Candidates may bring approved references and permitted tools into the testing center under the applicable examination rules.
The included International Mechanical Code supports preparation for mechanical equipment, refrigeration machinery rooms, ventilation, ducts, combustion air, chimneys, vents, and related installation requirements. NFPA 54 supports natural-gas questions, while NFPA 58 addresses liquefied petroleum gas systems.
Modern Refrigeration and Air Conditioning supports technical questions involving refrigeration, heating, air conditioning, heat pumps, controls, equipment operation, maintenance, and troubleshooting. HVAC Duct Construction Standards supports duct materials, construction, reinforcement, fittings, sealing, and supports. The Ductulator supports duct-sizing calculations.
Approved references may be highlighted, underlined, annotated, and indexed before the examination. Permanent tabs may be used to identify chapters, definitions, tables, fuel-gas provisions, refrigeration topics, ductwork subjects, equipment information, and other useful sections.
Temporary tabs, removable notes, loose papers, and inserted pages are not permitted. Candidates may not write in the references during the examination, and examination questions or answers may not be recorded inside approved materials.
All books included in this package arrive highlighted and permanently tabbed. Candidates should review every tab before test day, study the highlighted material, and learn how the references are organized. Prepared books are most useful when the candidate understands the subject connected to each marked section.
A practical open-book strategy begins by identifying the main subject. A mechanical-installation question may lead to the International Mechanical Code. A natural-gas piping, appliance, combustion-air, or venting question may lead to NFPA 54. An LP gas question may require NFPA 58.
Questions involving refrigeration principles, heat pumps, air-conditioning equipment, furnaces, controls, maintenance, or troubleshooting may be supported by Modern Refrigeration and Air Conditioning. Duct-construction questions may require the HVAC Duct Construction Standards, while duct-sizing questions may involve the Ductulator.
Candidates should use permanent tabs together with the table of contents, index, chapter headings, diagrams, and technical tables. Reading the complete section is important because exceptions, notes, definitions, and surrounding material may affect the correct answer.
Passing the examination does not automatically issue the D-2 license. Applicants must complete Connecticut’s training, application, examination, documentation, and license-issuance requirements.
The Connecticut D-2 credential is a limited journeyperson license for warm-air heating, air-conditioning, and refrigeration system work. The holder may perform qualifying installation, repair, replacement, maintenance, and alteration work within the scope of the credential.
The classification includes necessary piping for conveying heating or cooling media and associated pumping equipment. It also includes qualifying LP gas supplied by containers, natural-gas piping, approved gas appliances, gas-utilization equipment, and related accessories.
The D-2 license does not include the installation or servicing of oil burners of any size. License holders must remain within the work authorized by the credential and obtain any additional occupational license required for services outside the D-2 scope.
Sheet-metal work is included only as it relates to the limitations of the D-2 credential. The license does not provide unlimited authority to perform unrelated sheet-metal, plumbing, electrical, oil-burner, or other regulated work.
The D-2 license is a journeyperson credential and does not provide independent contracting authority. The holder performs authorized work while employed by or under the supervision of a contractor licensed for that work.
Applicants qualify through completion of a registered apprenticeship program or an equivalent experience-and-training pathway accepted by Connecticut. Supporting documentation may be required to establish classroom education, supervised on-the-job training, apprenticeship completion, or equivalent qualifications.
Applicants with experience, training, or occupational credentials obtained outside Connecticut should follow the applicable state application pathway. Connecticut determines whether submitted qualifications meet the requirements for examination eligibility and license issuance.
The following included references and tool are approved for applicable use during the Connecticut D-2 open-book examination:
Candidates are responsible for bringing the required references and tools to the examination center. All included books arrive highlighted and permanently tabbed for study and reference navigation.
A productive D-2 study plan should begin with fuel-gas systems and refrigeration because these are the two largest examination categories. Candidates should practice gas-pipe sizing, table navigation, combustion-air review, venting requirements, refrigeration-cycle principles, component functions, and troubleshooting concepts.
Use NFPA 54 to study natural-gas piping, sizing, pressure, appliance installation, regulators, combustion air, testing, and venting. Practice the longest-length method until the process can be completed accurately under timed conditions.
Use NFPA 58 to review LP gas containers, storage, regulators, piping, equipment, separation requirements, and installation safety. Learn how LP gas topics differ from natural-gas provisions and which reference applies to each system.
Use Modern Refrigeration and Air Conditioning to review refrigerants, compressors, condensers, evaporators, metering devices, heat pumps, furnaces, controls, chillers, pressure-temperature relationships, maintenance, and troubleshooting.
Use the Ductulator and HVAC Duct Construction Standards to study airflow, friction rate, velocity, duct sizing, materials, reinforcement, fittings, sealing, fabrication, and support requirements.
Use the International Mechanical Code for mechanical installation provisions involving equipment, machinery rooms, ventilation, combustion air, ducts, chimneys, vents, and related systems.
The online course provides a structured way to review these topics during one year of course access. Candidates can revisit difficult subjects, complete practice-oriented preparation, and use the highlighted and tabbed books to research supporting information.
Timed reference practice should include identifying the likely book before beginning a search. Candidates should use the permanent tabs to reach a major subject and then use the index, chapter headings, definitions, tables, and diagrams to locate the precise answer.
1 Exam Prep helps Connecticut D-2 candidates prepare with highlighted and tabbed rental references, one year of course access, a Ductulator, and Application Service in one coordinated package.
Trade-focused study guidance helps candidates review fuel gas, refrigeration, ductwork, heating and cooling principles, heat pumps, furnaces, controls, ventilation, chillers, combustion air, safety, and mechanical requirements in an organized sequence.
Practice-oriented preparation helps candidates connect questions with the correct reference, work through sizing problems, use technical tables, and identify weaker subjects before examination day.
The highlighted and tabbed books provide a practical navigation framework. Highlighting draws attention to useful provisions and technical explanations, while permanent tabs help candidates move between major chapters, definitions, tables, and examination subjects.
One year of course access gives candidates time to build a consistent study routine, revisit difficult material, and practice using the same rental references intended for open-book testing. Application Service supports organization of the Connecticut D-2 journeyperson license submission.
No exam-preparation or application service can guarantee examination eligibility, a passing score, application approval, or license issuance. Candidates remain responsible for satisfying Connecticut’s training requirements, submitting accurate documentation, preparing thoroughly, and completing all required licensing steps.
The package includes five highlighted and tabbed rental books, a Ductulator, one year of course access, and Application Service.
The package price is $2,315, plus a refundable $750 deposit. The total due today is $3,065.
The $750 deposit is fully refundable when the rental books are returned within the rental period in similar condition.
Yes. All included books are highlighted and permanently tabbed before delivery.
Please allow up to 15 business days for ultimate book package orders.
The package includes 1 year of course access.
Yes. Application Service is included to support organization of the applicable Connecticut D-2 journeyperson application.
Yes. Candidates may bring approved references and permitted tools into the examination center under the applicable testing rules.
The examination contains 60 questions. Candidates have two hours to complete the test and must earn a minimum score of 70 percent.
Fuel-gas systems are the largest category with 10 questions. Refrigerants and refrigeration follow with eight questions, and ducts account for six questions.
Yes. A Ductulator is included for duct-sizing, airflow, velocity, and friction-rate preparation.
No. The D-2 credential is a journeyperson license. The holder performs authorized work while employed by or under the supervision of an appropriately licensed contractor.
No. Applicants must meet Connecticut’s qualification requirements, receive examination eligibility, pass the examination, complete the licensing process, and receive state approval.