Prepare for the Georgia Conditioned Air Contractors Class II (Unrestricted) examination with ACE, the Free Demo Personal AI Tutor from 1 Exam Prep. Explore commercial HVAC systems, heating and cooling load calculations, duct design, refrigeration, gas piping, mechanical codes, electrical requirements, and contractor business practices through interactive, AI-supported study guidance.
Georgia Class II Conditioned Air Contractors work with residential and commercial heating, ventilation, and air conditioning systems. Their responsibilities require technical knowledge of equipment selection, system design, installation, maintenance, troubleshooting, and applicable construction codes.
The Class II (Unrestricted) classification provides broader contracting authority than Georgia's Class I (Restricted) classification, allowing qualifying contractors to undertake conditioned air projects without Class I equipment-capacity limits.
The Georgia Conditioned Air Contractors Class II (Unrestricted) Exam Prep Free Demo Personal AI Tutor introduces organized preparation for this comprehensive licensing examination.
ACE helps candidates explore HVAC concepts, understand technical terminology, review installation practices, and strengthen study habits through personalized AI-supported explanations.
Whether you are an experienced HVAC technician, commercial installer, service supervisor, mechanical contractor, or business owner pursuing Georgia Class II licensing, ACE offers an introduction to structured examination preparation.
Explore ACE: Meet Your Personal AI Exam Coach.
The Georgia Class II Conditioned Air Contractor examination is administered by PSI Services for the Georgia Construction Industry Licensing Board, Division of Conditioned Air Contractors.
The examination evaluates residential and commercial HVAC design, installation, maintenance, repair, safety, codes, and contractor management.
The examination includes both practical trade knowledge and questions requiring the use of technical reference books. A combination of code familiarity, calculation practice, and experience-based review is valuable.
The Georgia Conditioned Air Contractors Class II examination is an open book test. Candidates may bring the publications designated on the examination reference list.
Approved references cover Georgia gas and mechanical codes, electrical requirements, residential load calculations, duct design, refrigeration technology, HVAC business management, and construction safety.
The approved list also includes specialized design resources and a low-pressure boiler reference for Class II candidates.
Candidates may bring as many or as few of the designated references as they choose. However, unfamiliarity with their organization can make locating technical information difficult during a timed examination.
Reference books may be highlighted, underlined, and indexed using permanent tabs. Unauthorized photocopied materials, handwritten notes, and additional inserted materials are prohibited.
Study the table of contents, indexes, charts, and calculation tables in each relevant publication. Practice finding mechanical code provisions, gas piping requirements, and HVAC design information.
ACE supports preparation through organized explanations and reference-focused review. The AI tutor itself is not an approved examination-room resource.
Georgia Class II licensing involves meeting the qualification requirements established by the Division of Conditioned Air Contractors.
Businesses engaged in conditioned air contracting must also meet Georgia's applicable business registration and qualifying-licensee requirements.
The Georgia Construction Industry Licensing Board, Division of Conditioned Air Contractors regulates Class II conditioned air licensing.
Class I licenses are restricted to systems not exceeding 175,000 BTU of heating and 60,000 BTU of cooling. Class II licenses do not carry those equipment-capacity restrictions.
Georgia Class II applicants must establish five years of qualifying full-time conditioned air experience, including:
Georgia provides qualifying education credit under its licensing requirements. Applicants must also satisfy applicable training, EPA certification, experience-verification, and background-check provisions.
The Class II scope includes residential and commercial conditioned air systems such as split systems, package units, heat pumps, variable refrigerant flow systems, chillers, ventilation equipment, and associated components.
Installation of boilers remains subject to separate regulatory authority.
The unrestricted designation concerns the HVAC equipment and project scope. It does not eliminate the obligation to comply with building codes, permitting requirements, equipment standards, or other applicable laws.
The Georgia Class II examination uses designated reference publications covering HVAC installation, engineering fundamentals, and contractor responsibilities.
The following publications and designated calculation aids are permitted for the Georgia Class II examination:
The examination emphasizes four broad areas of professional conditioned air contracting:
System design accounts for more than half of the scored examination questions. Candidates should give particular attention to load calculations, airflow, duct sizing, and equipment selection.
Commercial HVAC design requires understanding building loads, equipment capacities, and system configuration.
Study heating and cooling calculations, ventilation needs, equipment selection, and building characteristics.
Review the principles behind designing systems for commercial spaces with varying occupancy, usage, and environmental conditions.
Load calculations help determine the heating and cooling capacity required for a building.
Study heat gain, heat loss, indoor conditions, outdoor design temperatures, and building characteristics.
Practice interpreting calculation tables and understanding the role of ACCA Manual J in residential design.
Proper duct design supports comfort, efficiency, and reliable system operation.
Study airflow requirements, friction loss, duct sizing, static pressure, and air distribution.
Review ACCA Manual D, flexible duct installation requirements, and duct sizing calculation aids.
Refrigeration knowledge is essential for both installation and troubleshooting.
Study compressors, condensers, evaporators, metering devices, refrigerant flow, and heat transfer.
Review superheat, subcooling, refrigerant circuit performance, and basic diagnostic procedures.
Fuel gas systems require safe piping, combustion air, venting, and equipment installation.
Study gas pipe sizing, appliance connections, venting principles, combustion air, and applicable Georgia Gas Code requirements.
Practice locating relevant code tables and installation provisions.
Class II preparation includes equipment and design topics associated with larger commercial installations.
Study chillers, cooling towers, water circulation, and selected low-pressure boiler fundamentals.
Review the relationship between mechanical equipment, supporting components, and system operating requirements.
HVAC systems rely on motors, contactors, relays, thermostats, and electrical controls.
Study electrical measurements, motor operation, control circuits, and equipment protection.
Review applicable National Electrical Code requirements for HVAC electrical installations.
Conditioned air contractors need practical knowledge of system startup, performance verification, and repairs.
Study equipment placement, refrigerant piping, condensate drainage, duct installation, and commissioning procedures.
Review methods for identifying system problems, checking operating conditions, and understanding equipment performance.
Class II contractors must understand professional responsibilities beyond technical HVAC work.
Study construction contracts, project scheduling, safety practices, bookkeeping, business administration, and regulatory compliance.
Become familiar with the designated business guide and OSHA construction safety requirements.
1 Exam Prep supports HVAC professionals preparing for licensing examinations through organized study guidance, trade-focused review, practice-oriented learning, and structured preparation.
With ACE, candidates can explore personalized AI-supported explanations involving load calculations, duct design, refrigeration, gas piping, electrical systems, and commercial HVAC equipment.
The Georgia Conditioned Air Contractors Class II (Unrestricted) Exam Prep Free Demo Personal AI Tutor introduces an interactive approach to reviewing technical subjects associated with Georgia's unrestricted conditioned air contractor classification.
ACE encourages students to revisit challenging concepts, strengthen reference-navigation skills, and develop a consistent study routine.
Whether you are transitioning from field installation into contracting, expanding your commercial HVAC knowledge, or preparing for Class II examination eligibility, ACE provides an introduction to focused technical learning.
Explore Georgia Class II Conditioned Air Contractor preparation with ACE by 1 Exam Prep. Visit the ACE Personal AI Exam Coach page to explore the free demo.
It is a free demonstration of ACE, the personal AI exam coach from 1 Exam Prep, introducing preparation guidance for Georgia's Class II Unrestricted Conditioned Air Contractor examination.
Yes. The examination permits designated technical and business reference publications under the approved examination-room rules.
The examination contains 100 scored questions and 20 additional unscored pretest questions.
Candidates have seven hours, divided into two parts of three and a half hours each.
Georgia requires a minimum examination score of 70.
PSI Services administers the examination for the Georgia Construction Industry Licensing Board's Division of Conditioned Air Contractors.
Class I is restricted by heating and cooling equipment capacity. Class II is unrestricted and includes qualifying residential and commercial conditioned air contracting.
Applicants must establish five years of qualifying experience, including commercial supervision, service work, and lead-mechanic installation experience.
Yes. System design is the largest examination category and includes commercial heating and cooling concepts, equipment selection, and airflow requirements.
The 2024 Georgia Mechanical Code with Georgia amendments is the designated mechanical code for examinations administered from May 1, 2026.
Yes. Low-pressure boiler fundamentals are included among the Class II-specific study subjects.
Yes. Georgia Class II applicants must satisfy the applicable EPA Section 608 technician certification requirements.
ACE introduces organized explanations covering HVAC design, installation, refrigeration, controls, codes, and contractor responsibilities.
No. Georgia's Division of Conditioned Air Contractors regulates licensing. ACE provides educational examination preparation support.
Visit the ACE Personal AI Exam Coach page to explore Georgia Class II Conditioned Air Contractor exam preparation.
Take the next step toward focused Georgia Conditioned Air Contractors Class II (Unrestricted) examination preparation. Explore the free ACE AI tutor demo and strengthen your understanding of commercial HVAC systems, load calculations, duct design, refrigeration, mechanical codes, electrical controls, and contractor responsibilities with 1 Exam Prep.